Download Print this page

EBA 486 ET Operating Instructions Manual page 35

Advertisement

Maintenance and cleaning
D
Danger! Disconnect the mains before
starting any service work or before
removing the cover.
Maintenance work may only be performed by
trained staff.
Grease the backgauge (A) control weekly with
a grease gun. Advance the backgauge as far
as possible to the front. (Use non-resinous oil
or grease).
Grease the remaining parts twice a year (see
picture).
The main switch must be on "0" (B).
Remove lower panel (C).
Tools in tool set or tool holder.
• Remove any paper.
• Grease the machine.
• Check the 4 joining bolts and 2 pushing bars
for wear (D). If necessary inform your service
personnel.
• Mount the machine.
= Greasing points on the machine.
- 35 -

Advertisement