Content Operation Notices The Refrigerant ......................1 Operation Environment ....................2 Safety Warning ......................2 Part's Name ......................4 Operation Guide Operation Introduction for Control Panel ..............5 Buttons on Remote Controller .................7 Introduction for Icons on Display Screen ..............7 Introduction for Buttons on Remote Controller ............8 Function Introduction for Combination Buttons ............10 Operation Guide ....................
Page 3
Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
Appliance filled with flammable gas R32. Before install and use the appliance, read the owner’s manual first. Before repair the appliance, read the service manual first. The Refrigerant To realize the function of the air conditioner unit, a special refrigerant circulates in the system.
Operation Environment ● The air conditioner must be operated within the temperature range: 16°C ~ 35°C. ● The appliance is for indoor use only. ● The appliance must be positioned so that the plug is accessible. ● This air conditioner can only be used for family, not for commercial industry.
Page 6
Safety Warning ● Cleaning and user maintenance shall not be made by children without supervision. ● Before operation, please confirm whether power specification complies with that on nameplate. ● Before cleaning or maintaining the air conditioner, please turn off air conditioner and pull out the power plug. ●...
Operation Introduction for Control Panel Name of control panel Dual-8 nixie tube Cool mode indicator + / - button Dry mode indicator Fan speed indicator Fan mode indicator Sleep button Timer button Mode button ON/OFF button Fan button Operation of control panel Note: After putting through the power, the air conditioner will give out a sound.
Page 9
Operation Introduction for Control Panel Mode button Press this button and the mode will circulate according to below sequence: COOL→DRY→FAN COOL: Under this mode, cooling mode indicator is bright. Dual-8 nixie tube displays set temperature. Temperature setting range is 16°C~30°C. DRY: Under this mode, drying mode indicator is bright.
Buttons on Remote Controller ON/OFF button MODE button +/- button FAN button X-FAN button SLEEP button TIMER button Introduction for Icons on Display Screen Timer on Timer off Sending signal X-fan operation Cool operation Sleep operation Dry operation Lock Fan operation Set speed Set temperature Set time...
Introduction for Buttons on Remote Controller Note: This is a general use remote controller, it could be used for the air conditioners ● with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
Page 12
Introduction for Buttons on Remote Controller FAN button Pressing this button can select fan speed circularly as: AUTO, SPEED 1 ( SPEED 2 ( ), SPEED 3 ( AUTO Note: ● Under Auto speed, air conditioner will select proper fan speed automatically according to ambient temperature.
Introduction for Buttons on Remote Controller Note: ● Timer setting range: 0.5~24h ● The interval between two motions can't exceed 5s, otherwise the remote con- troller will exit setting status. Function Introduction for Combination Buttons Child lock function Pressing “+” and “-” buttons simultaneously can turn on or turn off child lock function. When child lock function is started up, LOCK indicator on remote controller is ON.
Operation Guide After putting through the power, press "ON/OFF" button on remote controller to turn on the air conditioner. Press "MODE" button to select your required mode: COOL, DRY, FAN. Press "+" or "-" button to set your required temperature. (Temperature can’t be adjusted under auto mode).
Clean and Maintenance WARNING ● Before cleaning the air conditioner, please turn off the unit and disconnect power. Otherwise, it may cause electric shock. ● Do not wash air conditioner with water. Otherwise, it may cause electric shock. ● Do not use volatile liquid (such as thinner or gas) to clean the air conditioner. Otherwise, it may damage the appearance of air conditioner.
Page 16
Clean and Maintenance Clean heat discharge pipe Remove the heat discharge pipe from air conditioner, clean and dry it , and then reinstall it. (For the method of installation and removal , please refer to the instruction for "Installation and disassembly of heat discharge pipe"). Checking before use-season 1.
Malfunction Analysis Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon Troubleshooting Solution ● Power failure? ● Wait after power recovery. ● Is plug loose? ● Reinsert the plug. ●...
Page 18
Malfunction Analysis Phenomenon Troubleshooting Solution ● Whether air outlet or air inlet is ● Eliminate the obstacles. blocked? ● Under heating mode, whether ● The unit will stop blowing indoor temperature ireaches fan after reaching set set temperature? temperature. ● In order to prevent cold air, No fan blowed ●...
Page 19
Malfunction Analysis Malfunction code 1. Pour out the water inside chassis. Chassis is full of water. 2. If "H8" still exits, please contact professional person to maintain the unit. Malfunction of ambient Please contact professional person to deal temperature sensor. with it.
Installation Precaution WARNING ● Observe all governing codes and ordinances. ● Do not use damaged or non-standard power cord. ● Be caution during installation and maintenance. Prohibit incorrect operation to prevent electric shock, casualty and other accidents. Selection of installation location Basic requirement Installing the unit in the following places may cause malfuncti on.
Preparation before Installation Note: check if the accessories are available before installation. Accessory list Window Window Joint Adapter heat discharge pipe adapter(top) adapter(bottom) battery (AAA 1.5V) wire hook screw remote controller user's manual Optional Note: some models are without the following accessories. Window panel Exhaust cover Extension panel...
Install Wire Hook ● Assemble the wire hook at the back of the unit with screws (the direction of wire direction of wire hook is upward wire hook screw direction of wire hook is downward ● Wind the power cord around the wire hook.
Removing Collected Water There are 2 ways to remove collected water: Use the continuous drainage option from the bottom hole ■ Drainage way as follows. 1. In cooling or drying operation, the condensation water will be drained to the chassis and spattered by water-striking motor. As the temperature of condenser is high, most of the condensation water will be evaporated and drained to outdoor.
Page 24
Removing Collected Water Use the continuous drainage option from the middle hole Note: Water can be automatically emptied into a floor drain by attaching 14mm inner diameter hose (not included). 1. Remove the continuous drain cap 1 by turning it counter clockwise then remove the rubber stopper 2 from the spout.
Installation in a double-hung sash window(Optional) 1. Connect the rain guards to the insect guard net. Insert all three projections on each rain guard into the holes in the insect guard net. Side “A” will now be at the top, as indicated in the diagram. Hole Insect guard net Rain guard...
Page 26
Installation in a double-hung sash window(Optional) The window panel cannot be installed in windows less than 20.5" (520mm) wide, as you will be unable to shut the exhaust cover. (1) Open the window sash and place the window panel on the window sill. (2) Secure the window panel to the window stool with screws.
Page 27
Installation in a double-hung sash window(Optional) 5. Close the window sash securely against the Window panel. 6. Stuff the Foam seal A between the glass and the window to prevent air and insects from getting into the room. 7. Attach the bracket with a screw.(Recommended) Bracket Please lay a tabular material underneath the window panel in case you could not attach the rain guard or the window adapter properly due to the deep...
Installation in a sliding sash window(Optional) 1. Connect the rain guards to the insect guard net. Insert all three projections on each rain guard into the holes in the insect guard net. Side “A” will now be at the top, as indicated in the diagram. "A"...
Page 29
Installation in a sliding sash window(Optional) The window panel cannot be installed in windows less than 20.5" (520mm) high, as you will be unable to shut the exhaust cover. (1) Open the window sash and place the window panel on the window frame. (2) Secure the window panel to the window frame with screws.
Page 30
Installation in a sliding sash window(Optional) 4. Close the window sash securely against the Window panel. 5. Stuff the Foam seal A between the glass and the window to prevent air and insects from getting into the room. 6. Attach the bracket with a screw.(Recommended) Bracket Please lay a tabular material underneath the window panel in case you could not attach the rain guard or the window adapter properly due to the deep...
Installation and Disassembly of Heat Discharge Pipe Install heat discharge pipe 1. Install window adapter— aim the window adapter(top) at the window adapter(bottom),fix them together,press the clasp forcibly in to the groove. Window adapter(top) Window adapter(bottom) 2. Rotate joint and window adapter clockwise into the two ends of heat discharge pipe. clockwise clockwise joint...
Page 32
Installation and Disassembly of Heat Discharge Pipe Note of Installingheat discharge pipe The discharge pipe is suggested to be installed according to below figure by the manufacturer. correct under 51 inchs about 24 inchs User can adjust the installation method of the discharge pipe basing on the requirement, while the similar installation methods as below which will lead to unsmoothly air-out are not allowed.
Page 33
Installation and Disassembly of Heat Discharge Pipe Disassemble heat discharge pipe 1. Remove joint: Press the clasp and lift joint upwards to remove it. clasp upwards disassemble joint 2.Remove window adapter from outdoors. window adapter 3.Remove the window adapter. Pull out and remove the window adapter by pushing down two “PUSH”...
Operation Test ● Put through the power supply and then press ON/OFF button on remote contro- ller to start the unit. ● Press mode button to select auto, cooling, drying, fan or heating function, and then check if the unit operates normally. ●...
Safety operation of flammable refrigerant Qualification requirement for installation and maintenance man All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised by the person who bears the qualification for using the flammable refrigerant.
Page 36
Safety operation of flammable refrigerant Make sure the leak detector (calibrate the leak detector under the environment without refrigerant)won’t to be the potential ignition source and it’s applicable to the tested refrigerant. The set warning concentration for the refrigerant detection devices can’t exceed 25% of the concentration measuring range.
Page 37
United Kingdom www.sinclair-world.com The device was made in China (Made in China). REPRESENTATIVE, SERVICE SINCLAIR Global Group s.r.o. Purkyňova 45 Brno 612 00 Czech republic Phone - sales: +420 541 590 140 Phone - service: +420 541 590 150 www.ayrton-world.com info@ayrton-world.com...