Content Operation Notices The Refrigerant ......................1 Safety Warning ......................2 Operation Environment ....................3 Part's Name ......................4 Operation Guide Operation Introduction for Control Panel ..............5 Buttons on Remote Controller .................7 Introduction for Icons on Display Screen ..............7 Introduction for Buttons on Remote Controller ............8 Function Introduction for Combination Buttons ............12 Operation Guide ....................
Appliance filled with flammable gas R290. Before install and use the appliance, read the owner’s manual first. Before install the appliance, read the installation manual first. Before repair the appliance, read the service manual first. The Refrigerant To realize the function of the air conditioner unit, a special refrigerant circulates in the system.
Safety Warning ● This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Safety Warning ● Do not use an extension cord. ● Do not through sundries into the air duct. If there are sundries get into the air duct, please contact the professionals to deal with it. Operation Environment ● The air conditioner must be operated within the temperature range: 16°C ~ 35°C.
Operation Introduction for Control Panel Name of control panel Dual-8 nixie tube Cool mode indicator + / - button Dry mode indicator Fan speed indicator Fan mode indicator Sleep button Timer button Mode button ON/OFF button Fan button Operation of control panel Note: After putting through the power, the air conditioner will give out a sound.
Page 9
Operation Introduction for Control Panel Mode button Press this button and the mode will circulate according to below sequence: → COOL COOL: Under this mode, cooling mode indicator is bright. Dual-8 nix set temperature. Temperature setting range is 16°C~30°C. DRY: Under this mode, drying mode indicator is bright. Dual-8 nixie tube won’t display.
Buttons on remote controller ON/OFF button AUTO HEALTH X-FAN MODE button HUMIDITY FILTER +/- button TURBO FAN button HOUR ON/OFF button button ON/OFF MODE HEALTH SAVE button X-FAN button (Note: X-FAN is same with BLOW) TEMP button TIMER button X-FAN TEMP TIMER TURBO button...
Introduction for buttons on remote controller Note: ● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
Page 12
Introduction for buttons on remote controller Note: For preventing cold wind, after starting up heating mode, indoor fan will blow fan afterdelaying 1-5min. (Details time is decided by indoor ambient temperature) Temperature setting range on remote controller: 16℃ -30℃ . Fan speed setting range: auto, low speed, medium speed and high speed.
Page 13
Introduction for buttons on remote controller Note: When selecting " " with remote controller, it’s auto swing. Horizontal louver of air conditioner will swing up&down automatically at the maximum angle. When selecting " 、 、 、 、 swing. Horizontal louver of air conditioner will stop at that position as shown by the icon to swing.
Page 14
Introduction for buttons on remote controller SAVE function: Under cool mode, press SAVE button and the unit will operate under SAVE mode. Dual-8nixie tube on remote controller displays "SE". Air conditioner will operate at auto speed. Set temperature can’t be adjusted. Press SAVE button again to exit SAVE mode.
Introduction for buttons on remote controller hour. When holding "+" or "-" button, 2s later, the time will change quickly until to Cancel TIMER OFF: Press "TIMER" button again under TIMER OFF status. ● At OFF status, press this button once can set TIMER ON. Please refer to TIMER off for detailed operation.
Clean and Maintenance Clean heat discharge pipe Remove the heat discharge pipe from air conditioner, clean and dry it , and then reinstall it. (For the method of installation and removal , please refer to the instruction for "Installation and disassembly of heat discharge pipe"). Checking before use-season 1.
Malfunction Analysis Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon Troubleshooting Solution ● Power failure? ● Wait after power recovery. ● Is plug loose? ● Reinsert the plug. ●...
Page 20
Malfunction Analysis Phenomenon Troubleshooting Solution ● Whether air outlet or air inlet is ● Eliminate the obstacles. blocked? ● Under heating mode, whether ● The unit will stop blowing indoor temperature ireaches fan after reaching set set temperature? temperature. ● In order to prevent cold air, No air blowed ●...
Page 21
Malfunction analysis Malfunction code ERROR Troubleshooting CODE Please contact qualified professionals for service. Please contact qualified professionals for service. Please contact qualified professionals for service. Please contact qualified professionals for service. 1.Check if the unit is under high-temperature and high-humidity environment; if ambient temperature is too high, power off the unit and then energize it for operation after the ambient temperature drops to 35 below.
Installation Precaution WARNING ● Observe all governing codes and ordinances. ● Do not use damaged or non-standard power cord. ● Be caution during installation and maintenance. Prohibit incorrect operation to prevent electric shock, casualty and other accidents. Selection of installation location Basic requirement Installing the unit in the following places may cause malfunction.
Page 23
Installation Precaution Requirements for electric connection WARNING: Safety precaution 1. Must follow the electric safety regulations when installing the unit. 2. According to the local safety regulations, use qualified power supply circuit. 3. For appliances with type Y attachment,the instructions shall contain the substance of the following.If the supply cord is damaged,it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Preparation before Installation Note: check if the accessories are available before installation. Accessory list Window Window Joint Adapter heat discharge pipe adapter(top) adapter(bottom) AUTO HEALTH X-FAN HUMIDITY FILTER TURBO HOUR ON/OFF ON/OFF MODE battery X-FAN TEMP TIMER TURBO SLEEP LIGHT (AAA 1.5V) wire hook screw...
Install Wire Hook ● Assemble the wire hook at the back of the unit with screws (the direction of wire direction of wire hook is upward wire hook screw direction of wire hook is downward ● Wind the power cord around the wire hook.
Removing Collected Water There are 2 ways to remove collected water: Use the continuous drainage option from the bottom hole ■ Drainage way as follows. 1. In Cool or Dry mode operating, the condensation water will be drained to the chassis. 2.
Page 27
Removing Collected Water Use the continuous drainage option from the middle hole Note: Water can be automatically emptied into a floor drain by attaching 14mm inner diameter hose (not included). 1. Remove the continuous drain cap 1 by turning it counter clockwise then remove the rubber stopper 2 from the spout.
Installation in a double-hung sash window(Optional) 1. Connect the rain guards to the insect guard net. Insert all three projections on each rain guard into the holes in the insect guard net. Side “A” will now be at the top, as indicated in the diagram. Hole Insect guard net Rain guard...
Page 29
Installation in a double-hung sash window(Optional) The window panel cannot be installed in windows less than 20.5" (520mm) wide, as you will be unable to shut the exhaust cover. (1) Open the window sash and place the window panel on the window sill. (2) Secure the window panel to the window stool with screws.
Page 30
Installation in a double-hung sash window(Optional) 5. Close the window sash securely against the Window panel. 6. Stuff the Foam seal A between the glass and the window to prevent air and insects from getting into the room. 7. Attach the bracket with a screw.(Recommended) Bracket Please lay a tabular material underneath the window panel in case you could not attach the rain guard or the window adapter properly due to the deep...
Installation in a sliding sash window(Optional) 1. Connect the rain guards to the insect guard net. Insert all three projections on each rain guard into the holes in the insect guard net. Side “A” will now be at the top, as indicated in the diagram. "A"...
Page 32
Installation in a sliding sash window(Optional) The window panel cannot be installed in windows less than 20.5" (520mm) high, as you will be unable to shut the exhaust cover. (1) Open the window sash and place the window panel on the window frame. (2) Secure the window panel to the window frame with screws.
Page 33
Installation in a sliding sash window(Optional) 4. Close the window sash securely against the Window panel. 5. Stuff the Foam seal A between the glass and the window to prevent air and insects from getting into the room. 6. Attach the bracket with a screw.(Recommended) Bracket Please lay a tabular material underneath the window panel in case you could not attach the rain guard or the window adapter properly due to the deep...
Installation and Disassembly of Heat Discharge Pipe Install heat discharge pipe 1. Install window adapter— aim the window adapter(top) at the window adapter(bottom),fix them together,press the clasp forcibly in to the groove. Window adapter(top) Window adapter(bottom) 2. Rotate joint and window adapter clockwise into the two ends of heat discharge pipe. clockwise clockwise joint...
Page 35
Installation and Disassembly of Heat Discharge Pipe Note of Installingheat discharge pipe The discharge pipe is suggested to be installed according to below figure by the manufacturer. correct under 51 inchs about 24 inchs User can adjust the installation method of the discharge pipe basing on the requirement, while the similar installation methods as below which will lead to unsmoothly air-out are not allowed.
Page 36
Installation and Disassembly of Heat Discharge Pipe Disassemble heat discharge pipe 1. Remove joint: Press the clasp and lift joint upwards to remove it. clasp upwards disassemble joint 2.Remove window adapter from outdoors. window adapter 3.Remove the window adapter. Pull out and remove the window adapter by pushing down two “PUSH”...
Operation Test ● Put through the power supply and then press ON/OFF button on remote contro- ller to start the unit. ● Press mode button to select auto, cooling, drying, fan or heating function, and then check if the unit operates normally. ●...
Need help?
Do you have a question about the AYM-07P and is the answer not in the manual?
Questions and answers