Connecting A Vsr-880 To The Vs-2480 - Roland VM-7100 Connection Manual

Equipment connection and setting guide
Hide thumbs Also See for VM-7100:
Table of Contents

Advertisement

(20) Connecting a VSR-880 to the VS-2480

• Transferring audio via digital connection between the VSR-880 and the VS-2480.
• The VSR-880 can be controlled with the VS-2480.
Connection
fig.19
Equipment required
VS-2480 [internal IDE hard disk installed], VSR-880 [internal IDE hard disk installed]
Turning on the system
Connect the equipment and then turn the power on in the following order.
VSR-880
VS-2480
Settings
VS-2480
Projects setting screen
• Master Clock:
MIDI Parameter setting screen
• MMC Mode:
Sync/Tempo screen
• Sync Mode:
• EXT Sync SOURCE
VSR-880
[SHIFT]+[SYSTEM (
)]
• SYS MasterClk:
[SHIFT]+[SYSTEM (
)]
• SYS MID:MMC:
[SHIFT]+[SYSTEM (
)]
• SYS Syn:Source:
• SYS Syn:Gen:
[LEVEL/BALANCE]
• MST Direct Out:
[SHIFT]+[IN MIX (LEVEL BALANCE)]
• IN1 (2, 3, ... 8) Input=:
* Make the sampling rates of the VSR-880 and the VS-2480 the same.
O To record from the VS-2480 to the VSR-880
1. Set the track status of the VS-2480 to PLAY.
2. Set the input channels of the recording tracks of the VSR-880 to ON.
[SHIFT]+[TR MIX (EXT SYNC)]
Switch tracks with [SHIFT]+STATUS [1] to [8]. TR1 Assign IN1=On, TR2 Assign IN2=On, ...
3. Press [RECORD] on the VSR-880.
4. Press [PLAY] on the VS-2480.
5. To stop recording, press [STOP] on the VS-2480.
O To record from the VSR-880 to the VS-2480
1. Set the track status of the VS-2480 to REC.
2. Set the track status of the VSR-880 to PLAY.
3. Press [REC], and press [PLAY] on the VS-2480.
4. To stop recording, press [STOP] on the VS-2480.
26
VS-2480
[UTILITY]
(Page1) [F3(Proj)]
R-BUS1
[UTILITY]
(Page1) [F5(MIDI)]
MASTER
[UTILITY]
(Page1) [F6(SYNC)]
EXT
R-BUS1
"SYS System PRM?"
INT
[ENT/YES]
"SYS MIDI PRM?"
[ENT/YES]
Off/RBUS
"SYS Sync/Tempo ?"
INT
R-BUS
(PARAMETER [
][
On
(PARAMETER [
R-BUS
(PARAMETER [
R-BUS
R-BUS1
C
S
C
T
[ENT/YES]
(PARAMETER [
(PARAMETER [
[ENT/YES]
(PARAMETER [
])
][
])
"Input="
][
])
"Assign"
VSR-880
S
T
Sampling Clock
Control Signal
Time Code
][
])
][
])
][
])
[SHIFT]+STATUS [1] to [8]