Page 1
Read all warnings and instructions in this manual. Save these instructions. Model 232443 Shown 8162A 0359 II 1/2 G T3 GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 ITS03ATEX11251 Copyright 1999, Graco Inc. is registered to I.S. EN ISO 9001...
D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor. D Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
Page 4
Permanently coupled hoses cannot be repaired; replace the entire hose. D Use only Graco approved hoses. Do not remove any spring guard that is used to help protect the hose from rupture caused by kinks or bends near the couplings.
Page 5
WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding on page 7. D If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately.
D 307886, Fluid Pressure Regulator (included on 15:1 General Information Monarks only) NOTE: Reference numbers and letters in parentheses D 306565, Agitator (included on Models 232443, in the text refer to the callouts in the figures and the 232455, 232461, and 232467 only) parts drawing.
Page 7
2. Agitator (Models 232443, 232455, 232461, and ity. 232467 only): one end of the agitator ground wire (40, supplied) is fastened to the agitator motor with 9.
The bleed-type master air valve relieves air trapped between this valve and the pump after the valve is D The agitator (39), included on Models 232443, closed. Trapped air can cause the pump to cycle 232455, 232461, 232467, and 232473 only, keeps unexpectedly.
Page 9
Setup Detail of Fluid Regulator 101b (Ref) Model 232443 Shown SUPPLIED COMPONENTS 5 Gallon (19 liter) Pail Cover Pump 101a (Ref) Fluid Filter 8237A (includes fluid drain valve F) Air Relief Valve Pump Ground Wire (required; see page 7 for installation instructions)
Operation Pressure Relief Procedure Packing Nut Before starting, fill the packing nut 1/3 full with Graco WARNING Throat Seal Liquid (TSL) or compatible solvent. See your separate pump manual. INJECTION HAZARD The system pressure must be manually WARNING relieved to prevent the system from starting or spraying accidentally.
Page 12
Operation Agitator Operation (Models 232443, 2. When applying the fluid, keep the gun a consistent distance, about 8 to 12 inches (200 to 300 mm) 232455, 232461, and 232467 only) from the surface of the object being sprayed. 1. Slowly open the control valve (K) to start the Always hold the gun at a right angle from the agitator (39).
Maintenance Preventive Maintenance Schedule Flush with a fluid that is compatible with the fluid you are pumping and with the wetted parts in your system. The operating conditions of your particular system Check with your fluid manufacturer or supplier for determine how often maintenance is required.
Page 14
Parts Part No. 232443, Series A, 23:1 Monark, cst, with agitator, hose, and gun (shown) 10:1 and 15:1 Monarks include a fluid pressure regulator kit. Refer to page 18 for parts. If you order a new twin air/fluid hose (101), cut the coupling off one end of the red air hose so that the hose is 2 in.
Page 15
Parts 23:1 Monark Carbon Steel Packages, Part Nos. 232439, 232440, and 232443 23:1 Monark Stainless Steel Packages, Part Nos. 232451, 232452, and 232455 NOTE: Refer to page 16 for 10:1 and 15:1 Monark Packages. NOTE: Some packages include a hose and gun. Refer to page 19 for details.
Page 16
Parts 23:1 Monark Carbon Steel Packages, Part Nos. 232439, 232440, and 232443 23:1 Monark Stainless Steel Packages, Part Nos. 232451, 232452, and 232455 NOTE: Some packages include a hose and gun. Refer to page 19 for details. NOTE: To find the part number used in your package, read down the chart to find the desired ref. no., then read left to right to find the part number for your package.
Page 17
Parts 15:1 Monark Stainless Steel Packages, Part Nos. 232457, 232458, and 232461 15:1 Monark Carbon Steel Packages, Part Nos. 232463, 232464, and 232467 NOTE: These packages all include a fluid regulator kit. Refer to page 18. NOTE: Some packages include a hose and gun. Refer to page 19 for details. NOTE: To find the part number used in your package, read down the chart to find the desired ref.
Page 18
Fluid Regulator Parts 15:1 Monark Stainless Steel Packages, Part Nos. 232457, 232458, and 232461 15:1 Monark Carbon Steel Packages, Part Nos. 232463, 232464, and 232467 NOTE: The following part numbers apply only to packages supplied with a fluid regulator. Part numbers vary by package.
Page 19
Hose and Gun Parts 23:1 Monark Carbon Steel Packages, Part Nos. 232439 and 232443 23:1 Monark Stainless Steel Packages, Part Nos. 232451 and 232455 15:1 Monark Stainless Steel Packages, Part Nos. 232457 and 232461 15:1 Monark Carbon Steel Packages, Part Nos. 232463 and 232467 NOTE: The following part numbers apply only to packages supplied with a hose and gun.
Page 21
Dimensions Model 232439 Shown (hose and gun not shown) 8164A A (height) B (diameter of pail) Weight 32 in. (813 mm) 10.625 in. (270 mm) 47 lb (21 kg) 308766...
Technical Data Performance Charts To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow To find Pump Air Consumption (m#/min or scfm) at a specific fluid (lpm/gpm) and operating air pressure (psi/MPa/bar): flow (lpm/gpm) and air pressure (psi/MPa/bar): 1. Locate desired flow along bottom of chart. 1.
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.