Download Print this page
Napoleon W175-0689 Instruction Manual

Napoleon W175-0689 Instruction Manual

Fuel conversion kit for model c/gdi3 / c/gdi3e / c/gdix3

Advertisement

Available languages

Available languages

Quick Links

INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.
CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.
C/GDI3 / E
Kit W175-0687 / W175-0724 NG to P Includes:
1x
REGULATOR
1x
#53 BURNER ORIFICE
1x
CONVERSION DATA LABEL
1x
PROPANE PILOT INJECTOR
C/GDIX3
Kit W175-0689 NG to P Includes:
1x
REGULATOR
1x
#52 BURNER ORIFICE
1x
CONVERSION DATA LABEL
1x
PROPANE PILOT INJECTOR
This conversion kit shall be installed by a qualifi ed service agency in accordance with the
manufacturer's instructions and all applicable codes and requirements of the authority having
jurisdiction. If the information in these instructions is not followed exactly, a fi re, explosion or
production of carbon monoxide may result causing property damage, personal injury or loss
of life. The qualifi ed service agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the converted appliance is checked
as specifi ed in the owner instructions supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally ap-
proved with this appliance may result in property damage or personal injury.
CAUTION: Before proceeding with the conversion, shut off the gas supply fi rst and then disconnect the electrical
power.
1. Remove the door, logs, and panels from the ap-
pliance (see the "fi nishing" section of your installa-
tion manual).
2. Remove the 7 screws that secure the log cover in
place. Lift the cover out (Fig. 1).
3. Remove the 2 screws holding the burner tube,
then slide it to the left, up, and out (Fig. 2).
4. Remove the orifi ce and replace it with the orifi ce
supplied (use pipe thread compound).
5. Adjust the air shutter according to the table lo-
cated on the back of this page.
6. To convert the main valve to the desired fuel, fol-
low the instructions that are supplied with the SIT regulator assembly.
7. Remove the pilot hood from the pilot assembly by pulling vertically. Use an Allen key to unscrew the
injector (Fig. 3). Replace the pilot injector with the one supplied. Re-assembly the pilot hood onto
the assembly ensuring key position for proper alignment.
8. The conversion data label must be fi lled out and attached adjacent to the valve.
9. Turn on the gas supply and check for gas leaks by brushing on a soap and water solution.Do not
use open fl ame.
10. Re-install the burner and log cover, then light the pilot and main burner to ensure that the gas lines
have been purged. Purge all gas lines with the glass door off. Refer to the lighting instructions in
your appliance installation manual. Once all systems have been checked, replace the logs.
11. Ensure there is a continuous fl ow at the burner before replacing the door. Turn on all electrical
supply to the appliance.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada •
FUEL CONVERSION KIT FOR MODEL
C/GDI3 / C/GDI3E / C/GDIX3
These kits are for use at altitudes of 0 to 4500 feet.
Fig. 1
C/GDI3 / E
Kit W175-0692 / W175-0725 P to NG Includes:
1x
REGULATOR
1x
#43 BURNER ORIFICE
1x
CONVERSION DATA LABEL
1x
NATURAL GAS PILOT INJECTOR
C/GDIX3
Kit W175-0694 P to NG Includes:
1x
REGULATOR
1x
#37 BURNER ORIFICE
1x
CONVERSION DATA LABEL
1x
NATURAL GAS PILOT INJECTOR
Fig. 2
1(866)820-8686
PILOT
HOOD
PILOT
Fig. 3
INJECTOR
SPRING
CLIP
W415-1918 / B / 01.09.20
www.napoleon.com

Advertisement

loading

Summary of Contents for Napoleon W175-0689

  • Page 1 11. Ensure there is a continuous fl ow at the burner before replacing the door. Turn on all electrical supply to the appliance. W415-1918 / B / 01.09.20 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 •...
  • Page 2 FLAME MUST ENVELOP UPPER 3/8” TO 1/2” OF FLAME SENSOR MILLIVOLT ELECTRONIC (C/GDI3E / (C/GDI3) C/GDIX3) OLKIX3 Log Set (C/GDIX3) W415-1918 / B / 01.09.20 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...
  • Page 3 11. Assurez-vous que l’arrivée de gaz au brûleur est continue avant de fermer la porte. Rétablissez l’alimentation électrique à l’appareil. W415-1918 / B / 01.09.20 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 •...
  • Page 4 THERMOCOUPLE ET DE LA THERMOPILE DE 3/8” À 1/2”. ELECTRONIQUE MILLIVOLT (C/GDI3E / (C/GDI3) C/GDIX3) Ensemble de Bûche OLKIX3 (C/GDIX3) W415-1918 / B / 01.09.20 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • 1(866)820-8686 • www.napoleon.com...