Dean Forge Fabrication Ltd. Dean Prior, Buckfastleigh, Devon TQ11 0LS
T e l: 0 1 3 6 4 6 4 3 5 7 4
w w w.d e a n–f o r g e.c o.u k
e m a i l: s t o v e s @ d e a n-f o r g e.c o.u k
Operating Instructions for the Dean Stoves Hembury Slimline and
E
Hembury Slimline 5 S
th
(HEMSL5SE (issue 1) 25
April 2014)
All stoves meet the essential type test requirement BS EN13240:2001 + and
2:2004, CE marked
The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or part of the district of the
authority to be a smoke control area. It is an offence to emit smoke from a chimney of a
building, from a furnace or from any fixed boiler if located in a designated smoke control area.
It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area
unless it is used in an "exempt" appliance ("exempted" from the controls which generally apply
in the smoke control area).
The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to
authorise smokeless fuels or exempt appliances for use in smoke control areas in England. In
Scotland and Wales this power rests with Ministers in the devolved administrations for those
countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, applies in
Northern Ireland. Therefore it is a requirement that fuels burnt or obtained for use in smoke
control areas have been "authorised" in Regulations and that appliances used to burn solid
fuel in those areas (other than "authorised" fuels) have been exempted by an Order made and
signed by the Secretary of State or Minister in the devolved administrations.
The Dean Stoves, Hembury slimline 5 SE has been recommended as suitable for use in
smoke control areas when burning wood logs. To use the Hembury slimline 5 SE in smoke
controlled areas the smoke control kit must be fitted to the stove.
Further information on the requirements of the Clean Air Act can be found here :
http://smokecontrol.defra.gov.uk/
Your local authority is responsible for implementing the Clean Air Act 1993 including
designation and supervision of smoke control areas and you can contact them for details of
Clean Air Act requirements
Important
You will find an H shaped plate with holes drill in it, situated on the top of the main grate. This
grate is design to retain the ash when burning wood only and must NOT be use when burning
solid fuel (smokeless fuel or similar) or a mixture of wood and solid fuel. This plate can be
lifted out prior to lighting the fire, if required. Although the stove will burn wood straight on
the solid fuel grate, the H shaped plate retains the ash and helping to give a slower and hotter
burn. The ash can be pulled forward and pushed to the back, where it will drop though to the
ash pan. Always leave a small layer of ash on the plate.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hembury Slimline and is the answer not in the manual?

Questions and answers

Summary of Contents for Dean Hembury Slimline

  • Page 1 The Dean Stoves, Hembury slimline 5 SE has been recommended as suitable for use in smoke control areas when burning wood logs. To use the Hembury slimline 5 SE in smoke controlled areas the smoke control kit must be fitted to the stove.
  • Page 2: Safety Note

    Unpacking Stove Remove all packaging and stickers, Check the protective brick lining and the baffle plate has not move in transit. Remove the glove pack and operating tool from the inside of the stove. Safety Note Warning- The external parts of the appliance will get very hot to the touch and due care will be needed when operating.
  • Page 3: Controlling The Stove

    Controlling the stove Diagram A: Primary and secondary air controls situated below the door Primary = One slot Secondary = Two slots The primary air control is indicated with a single slot. This control is used for lighting the fire or boosting the fire.
  • Page 4 When the fire has fully established and the logs are burning well shut the primary air vent and control the fire with the secondary air wash lever (if you are unable to sustain the fire with secondary control it is very likely that your logs have a high moisture content). Refuelling When refuelling the fire, to ensure clean burning, the primary air control should be opened for a couple of minutes so that flames are established on the newly fuelled logs.
  • Page 5: Pre-Season Check

    Lighting The Stove With Solid Fuel Remove the H shaped woodburning plate if in place. Lay a fire of sticks and paper, establish the fire and then add the appropriate smokeless fuel and use the primary air control as the main control. If using a mixture of wood and coal, balance the primary and secondary control to achieve the desired fire.
  • Page 6 Notes Down draughts In adverse weather conditions down a draught may occur this could make the stove smoke, if this should happen shut all the stove air controls. If this occurs on a regular basis call in your engineer. It is possible a chimney cowl could cure this problem. Air vents Check periodically that the exterior ventilation grill is clear.
  • Page 7: Health And Safety Precautions

    As with all stoves fireguards must be installed when young children are present. Chimney All Dean Stoves must have a minimum chimney height of 4m measuring from the stove outlet, the chimney must not be less than 150mm (6”) internal diameter.
  • Page 8: Register Plates

    Stove Type Minimum from back of Minimum from side of appliance to combustibles appliance to combustibles Hembury Slimline 5 SE 400 mm (with optional heat 500 mm shield) 1000 mm (without heat shield) It may be necessary to shield a beam or mantle piece from the heat. The single wall flue must be at least 3 times its diameter away from combustible materials i.e.
  • Page 9 The Hembury Slimline 5 SE model requires a 125mm (5”) first length of flue then stepping up into a minimum of 150mm (6”) liner. When the Hembury Slimline 5 SE has a smoke except air slider fitted the flue liner can be reduced to 125mm (5”). We strongly advise a 150mm (6”) flue liner be fitted when possible.
  • Page 10: Data Plate

    DEFRA screw and close combustion manifold. The Hembury Slimline 5SE is supplied with a DEFRA screw fitted and must be left in place when using the stove in smoke controlled areas. This screw can be removed when installed in a non-smoke controlled area and a minimum of 150mm diameter flue is fitted to the stove.
  • Page 11 Table of mean flue temperatures with closed doors Stove Type Flue gas temp down stream of spigot, closed doors. Wood logs Ancit Hembury Slimline 5 SE 218 °C 282 °C Flue Gas Mass Flow Stove Type Flue gas mass flow (g/s)
  • Page 12: Ec Declaration Of Conformity

    EC Declaration Of Conformity The Undersigned, representing the following: Manufacturer Dean Forge Ltd Dean Prior, Buckfastleigh, Devon, TQ11 0LS Herewith declare that the products: Description Product Code Hembury 5 STDFHE5MF Hembury 5 Slimline STDFHE5SLMF Hembury 6 STDFHE6MF Hembury 8 STDFHE8MF Description of product: Hembury multifuel heating stove product range.
  • Page 13 Product Fiche according to Commission Delegated Regulation (EU)2015/1187 Energy Labelling of Local Space Heaters Supplier's Name Dean Stoves Model Hembury Slimline 5 Slimline 5 Energy Efficiency Class Nominal Heat Output to Room (KW) Nominal Heat Output to Water (KW) Seasonal Space Efficiency (%) 71.6...
  • Page 14 THE DEAN FORGE FABRICATION LTD STOVES GUARANTEE Dean Forge Fabrication Ltd offers a five year guarantee which covers the main body of the stove for manufacturing defects. In the event of any failure we will replace any defective part free of charge, labour cost excluded.
  • Page 16: Product Registration

    ..........................................................Phone Number: ..........Suppliers Details: Name ......................Address ...............................................................................Phone Number: ..........Installers Details: Name ......................Address ...............................................................................Phone Number: ..........HETAS Registration Number……………………………………………………. Dean Forge Fabrication Ltd Dean Prior Buckfastleigh Devon TQ11 0LS...

This manual is also suitable for:

Hembury slimline 5 se

Table of Contents