Advertisement

READ MANUAL BEFORE OPERATING SYSTEM
Read the owner's manual thoroughly before operating to ensure the
ATTENTION INSTALLER: Please be sure this manual and warranty information are
left with the power unit or customer when installation is complete.
Operating Instructions For
VACUFLO
FC300, FC550, FC650, FC1550
260, 466Q, 566Q, 760, 960
DB3000, DB5000, DB7000,
DB8000, DB9000, MAXAIR
512 West Gorgas Street • Louisville, OH 44641-3912
1-800-822-8356 • www.vacuflo.com
Dealer Name _____________________________________________
Dealer Phone _____________________________________________
Serial Number ____________________________________________
most efficient use of the system.
Central Vacuum Models:
®
®
P/N 8773-03 • 7/16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FC300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vacuflo FC300

  • Page 1 Operating Instructions For VACUFLO Central Vacuum Models: ® FC300, FC550, FC650, FC1550 260, 466Q, 566Q, 760, 960 DB3000, DB5000, DB7000, DB8000, DB9000, MAXAIR 512 West Gorgas Street • Louisville, OH 44641-3912 1-800-822-8356 •...
  • Page 2 VACUFLO Central Vacuums ® Models UL FILE REF. # ETL FILE REF. # FC300 77100 FC550 77125 FC650 77130 FC1550 77250 466Q 566Q DB3000 77400 DB5000 77500 DB7000 77600 DB8000 77800 DB9000 88200 MAXAIR 88100...
  • Page 3: Table Of Contents

    General Maintenance ..............6 * Emptying the Dirt Canister and Replacing the Filter Cartridge ..7 Filtered Cyclonic Models FC300, FC550, FC650 and FC1550 * Emptying the Dirt Canister and Cleaning the Guard Screen .... 8 True Cyclonic Models 260, 466Q, 566Q, 760, 960 and MaxAir * Bag Removal and Replacement ............
  • Page 4: Important Safety Instructions

    VACUFLO Central Vacuums ® IMPORTANT SAFETY INSTRUCTIONS Read These Instructions Before Using This Vacuum System Installation of this product should be made by a qualified, authorized central vacuum dealer. Before installing, using, or servicing this product, the installer should carefully read and fully understand the instructions including all warnings, cautions, and safety notice statements.
  • Page 5: Grounding Instructions

    Grounding method for: FC1550, DB9000 & MaxAir Models FC300, FC550, FC650, 260, 466Q, 566Q, DB3000, DB5000, DB7000 & DB8000 are for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug in Fig. A.
  • Page 6: General Information

    • Do not allow the motor to remain “on” unless a hose is connected or an inlet valve is open. If airflow is not permitted to flow through fan blades, motor damage may occur. • Do not operate without the filter in place (models FC300, FC550,650, FC1550). Change the filter cartridge (part number 8106-01 or 8107-01) once a year.
  • Page 7: Emptying The Dirt Canister And Replacing The Filter Cartridge

    (Figure #3) 4. Remove the old filter and replace it with a new pleated filter. Use filter part number 8106-01 for models FC300, FC550 and FC650 and filter part number 8107-01 for model FC1550. (Figure #4) Figure #3 5.
  • Page 8: Emptying The Dirt Canister And Cleaning The Guard Screen

    VACUFLO Central Vacuums ® Emptying the Dirt Canister & Cleaning the Guard Screen For True Cyclonic Models: 260, 466Q, 566Q, 760, 960 & MaxAir The dirt canister – where the vacuumed dirt is deposited – is the removable lower portion of the power unit.
  • Page 9: Bag Removal And Replacement

    VACUFLO Central Vacuums ® Bag Removal & Replacement For Disposable Bag Models: DB3000, DB5000, DB7000, DB8000 & DB9000 The dirt canister is the removable lower portion of the power unit. Follow these steps (refer to Figures #1, #2, #3 and #4) Make sure the power unit is OFF.
  • Page 10: Troubleshooting

    • If necessary, contact the qualified servicing dealer written on the front of this manual or locate an authorized dealer online at www.vacuflo.com to perform required maintenance. Obtaining Service Under Warranty: To obtain repair on warranted parts contact the seller...
  • Page 11: Importantes Mesures De Securité

    VACUFLO Central Vacuums ® IMPORTANTES MESURES DE SECURITÉ Lisez Complètement Le Mode D’emploi Avant D’utiliser Ce Système D’aspirateur. L’installation de ce produit doit être effectuée par un marchand d’aspirateur central autorisé. Avant l’installation, l’utilisation ou l’entretien de ce produit, l’installateur doit lire attentivement et de bien comprendre les instructions, y compris tous les avertissements, mises en garde et énoncés...
  • Page 12: Instructions De Mise À La Terre

    Figure B une prise adéquate par un électricien qualifié. METHODE DE MISE Á LA TERRE Les appareils, modéle FC300, FC550, FC650, 260, 466Q, FC1550, DB9000 & MaxAir 566Q, DB3000, DB5000, DB7000 & DB8000 doivent être employés avec un circuit de 120 volts et avoir une prise qui ressemble à...
  • Page 13: Warranty

    (c) any VACUFLO System or attachment which has been altered or modified in any way; (d) any VACUFLO System or attachment which has been damaged due to misuse, negligence, accident, or improper operation; (e) any damage due to shipping and handling; (f) any damage due to installation or faulty installation;...
  • Page 14 AS A CONDITION PRECEDENT TO WARRANTY COVERAGE HEREUNDER, YOU MUST PROVIDE PROOF OF PURCHASE OR HAVE REGISTERED THE VACUFLO CENTRAL VACUUM POWER UNIT BY TELEPHONE AT 1-800-822-8356 OR ONLINE AT www.cvacregistration.com, OR BY COMPLETING AND MAILING THE WARRANTY REGISTRATION CARD.