Kenmore Lift-Up DU5092 Use & Care Manual
Kenmore Lift-Up DU5092 Use & Care Manual

Kenmore Lift-Up DU5092 Use & Care Manual

Bagless upright vacuum with hair eliminator brushroll
Hide thumbs Also See for Lift-Up DU5092:

Advertisement

Quick Links

Use & Care Guide
Manual de Uso y Cuidado
Manuel d'entretien et d'utilisation
Lift-Up
Bagless Upright Vacuum
with Hair Eliminator
Aspiradora vertical sin bolsa con
Hair Eliminator
Aspirateur vertical sans sac équipé
d'un Hair Eliminator
Model/Modelo/Modèle: DU5092
Vacuum Cleaner Help Line:
1-877-531-7321 (US) / 1-844-608-3081 (CA)
8:00am-5:00pm EST, M-F
www.kenmorefloorcare.com
Brushroll

Advertisement

Table of Contents
loading

Summary of Contents for Kenmore Lift-Up DU5092

  • Page 1 Use & Care Guide Manual de Uso y Cuidado Manuel d'entretien et d'utilisation Lift-Up ™ Bagless Upright Vacuum with Hair Eliminator Brushroll ™ Aspiradora vertical sin bolsa con Hair Eliminator ™ Aspirateur vertical sans sac équipé d’un Hair Eliminator ™ Model/Modelo/Modèle: DU5092 Vacuum Cleaner Help Line: 1-877-531-7321 (US) / 1-844-608-3081 (CA)
  • Page 2: Table Of Contents

    Requesting Assistance or Service ..............Back Cover BEFORE USING YOUR NEW VACUUM CLEANER Read this Use & Care Guide. It will help you assemble and operate your new Kenmore vacuum cleaner in the safest and most effective way. For more information about vacuum cleaner care and operation, call the Vacuum Cleaner Help Line at 1-877-531-7321 (US) / 1-844-608-3081 (CA).
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Read all instructions in this guide before assembling or using your vacuum cleaner. WARNING! Your safety is important to us. To reduce the risk of fire, electrical shock, injury to persons or damage when using your vacuum cleaner, follow basic safety precautions including the following: •...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS Proper assembly and safe use of your vacuum cleaner are your responsibilities. Your vacuum cleaner is intended for Household use. Read this Use & Care Guide carefully for important use and safety information. This guide contains safety statements under warning and caution symbols.
  • Page 5: Vacuum Cleaner Warranty

    WITH PROOF OF SALE a defective product will be replaced free of charge. The Kenmore brand is used under license. Direct all claims for warranty service to: 1-877-531-7321 (US) / 1-844-608-3081 (CA). This warranty does not cover filters or belts, which are expendable parts that can wear out from normal use within the warranty period.
  • Page 6: Parts And Features

    PARTS AND FEATURES It is important to know your vacuum cleaner’s parts and features to assure its proper and safe use. Review these before using your vacuum cleaner. REPLACEMENT PARTS Item Part No.(US) Part No.(CA) Foam Filter 561055105 561055105 Felt Filter 561055106 561055106 HEPA Media Exhaust Filter...
  • Page 7 PARTS AND FEATURES ® Pet HandiMate 3-in-1 Combination Tool Handle Lift Up Flexible Button Hose On/Off Suction Upper Handle Switch Control Cord Release Hook Button Wand Dust Cup Release Button Carrying Wand Handle Hose Release Release Dust Cup Button Power Lid Release Button Cord...
  • Page 8: Assembly Instructions

    ASSEMBLY INSTRUCTIONS Before assembling the vacuum cleaner, check the PACKING LIST (page 2). Use this list to verify that you have received all the components of your new Kenmore Bagless Upright Vacuum Cleaner. 1. To place the body onto the nozzle, carry 3.
  • Page 9 ASSEMBLY INSTRUCTIONS NOTE: NOTE: DO NOT tilt the wand to insert it Make sure to wrap the power into the nozzle neck. cord around the upper cord hook first, and then around the lower cord hook to avoid DO NOT insert the wand before placing damaging the power cord.
  • Page 10: Operating Instructions

    OPERATING INSTRUCTIONS CAUTION Moving parts! To reduce the risk of personal injury, DO NOT touch the brushroll when vacuum is on. Contacting the brushroll while it is rotating can cut, bruise or cause other injuries. Always turn off after operation. Use caution when operating near children or pets.
  • Page 11 POWER CORD - RELEASE & USE 7. To restore power cord after use, turn WARNING upper cord hook to the upright position. Then wrap cord loosely around cord Electrical Shock and Personal Injury hooks. Hazard Wrapping the cord too tightly puts stress on the cord and can cause cord damage.
  • Page 12 OPERATION MODES NOTE: ABOVE FLOOR MODE The brushroll rotates when the vacuum cleaner is in the “II” position. 1. Place the vacuum cleaner in the upright locked position. 4. Once the vacuum is on, operate the vacuum cleaner by tilting the wand back 2.
  • Page 13 OPERATION MODES 4. Choose the desired attachment and CAUTION insert it into the wand. When using attachments, be careful not to over extend the stretch hose when reaching. Trying to reach beyond the hose stretch capability could cause the vacuum cleaner to tip over. CAUTION DO NOT pull the vacuum cleaner around the room by the hose.
  • Page 14 OPERATION MODES CAUTION CAUTION When using attachments, be careful not DO NOT pull the vacuum cleaner to over extend the stretch hose when around the room by the hose. Property reaching. Trying to reach beyond the damage or personal injury could result. hose stretch capability could cause the vacuum cleaner to tip over.
  • Page 15: Performance/Safety Features

    ATTACHMENTS To return the combination tool to crevice tool mode, press the release button and slide the brush tool down the combination tool. ® PET HANDIMATE ® The Pet HandiMate can be attached to the end of the handle and the wand. ®...
  • Page 16 PERFORMANCE/SAFETY FEATURES BRUSHROLL RESET CAUTION The brushroll has built-in protection against Always return the vacuum cleaner to motor damage should the brushroll jam. the upright position before using the If the brushroll slows down or stops, the hose and attachments. Failure to do brushroll overload protector shuts off the so may result in overheating of the brushroll motor and the brushroll indicator...
  • Page 17: Vacuum Maintenance And Care

    VACUUM MAINTENANCE AND CARE Always follow all safety precautions when performing maintenance to the vacuum cleaner. WARNING WARNING The motorized nozzle is equipped with Electrical Shock and Personal Injury sharp comb teeth inside. DO NOT touch Hazard comb teeth when servicing or cleaning Disconnect electrical supply before the vacuum, or it may cause personal servicing or cleaning the vacuum...
  • Page 18 EMPTYING DUST CUP 3. Position dust cup area of vacuum over WARNING a waste receptacle. Press down on the dust release button to open dust cup lid Always unplug power cord from and allow contents to drop into waste electrical outlet before performing any receptacle.
  • Page 19 PRE-FILTER CLEANING The pre-filter is located inside the dust cup. Clean the pre-filter as needed to optimize suction power. If suction remains weak after tapping the pre-filter clean, it will be necessary to wash it to clean off accumulated dust or hair. It is also recommended to wash the pre-filter every three months.
  • Page 20 FOAM AND FELT FILTERS CLEANING It is recommended to clean the foam and 4. Replace foam and felt filters into the felt filters with cold water every three vacuum cleaner. months. NOTE: When the cleaning of filters no longer restores vacuum cleaner suction to full power, or the filters are worn or broken, replace the filters.
  • Page 21 HEPA MEDIA EXHAUST FILTER CLEANING It is recommended to clean the HEPA 4. Reinstall the HEPA media exhaust filter media exhaust filter with cold water every into the vacuum cleaner. year. NOTE: When the cleaning of the filter no longer restores vacuum cleaner suction to full power, or the filter is worn or broken, replace the exhaust filter.
  • Page 22 ® PET HANDIMATE CLEANING WARNING Always unplug the power cord from an electrical outlet before performing maintenance to the vacuum cleaner. Cut off any carpet pile and lint entangled around brushroll with a pair of scissors. CAUTION To reduce the risk of injury from moving ®...
  • Page 23 REMOVING CLOGS CHECKING CONNECTION HOSE FOR CLOGS To separate the body from the nozzle, press the Lift-Up button and lift up the body. Lift-Up Button 1. Check and remove any clogs in the connection hose. 2. Reattach the nozzle onto the vacuum body.
  • Page 24: Troubleshooting

    TROUBLESHOOTING Review this table to find do-it-yourself solutions for minor performance problems. Any service needed, other than maintenance described in this Use & Care Guide, should be performed by a qualified service agent. WARNING Disconnect electrical supply before performing maintenance to the vacuum cleaner. Failure to do so could result in electrical shock or personal injury.
  • Page 25 TROUBLESHOOTING Position dust cup correctly and snap firmly in Dust cup is not installed correctly. place. HEPA media exhaust filter is Check exhaust filter for correct installation. Dust escapes installed incorrectly. Follow instructions on page 21. from vacuum. Foam filter, felt filter or HEPA Check and replace the foam filter, felt filter or media exhaust filter is worn or the HEPA media exhaust filter.

Table of Contents