Step
Screw (quantity)
2
M1.98 × 3 mm, flat-head, nylon-coated (4)
When installing:
• Ensure that the connector is attached firmly.
• Ensure that the base cover assembly is secured in place. Otherwise, the battery connection may fail.
1060 I/O bracket
For access, remove this FRU:
• "1020 Base cover assembly" on page 70
Removal steps
Step
Screw (quantity)
1
M1.98 × 3 mm, flat-head, nylon-coated (1)
1070 Thermal fan assembly
For access, remove this FRU:
• "1020 Base cover assembly" on page 70
Removal steps
Color
Torque
Silver
0.181 Nm
(1.85 kgf-cm)
Color
Torque
Silver
0.181 Nm
(1.85 kgf-cm)
.
Chapter 8
Removing or replacing a FRU
77