Case Cleaning ................. 14 Maintenance..............15 The serial number and shipping date of all equipment Evaporator Fans ..............15 has been recorded in Hussmann’s files for warranty and Copper Coils ................15 replacement part purposes. All correspondence pertaining Tips and Troubleshooting ............15 to warranty or parts ordering must include the serial number Stainless Steel Cleaning and Care..........
Cut and Plan Views Optional Ref. High Center Divider and Ref. Lighted Shelves 30" Optional Base Display Optional 11" Base Display DBRP-03 " " " Shown with Optional " Ref. High Center Divider and DBP-03 Refrigerated Lighted Shelves Standard Section Scale = 3/8”...
Installation (Cont'd) Setting and Joining 7. Apply bead of silicone to side of either half of case The sectional construction of these models enable them to (if case is built in two pieces). Also apply silicone to be joined in line to give the effect of one continuous display. seam between overhead light tubes.
Installation (Cont'd) Bumper Installation Instructions Step 2: Use silicone lubricant to help the Step 1: Make sure the aluminum channel and end caps bumper slide into the channel. are installed. Step 3: Starting on one end: while inserting the bumper, Step 4: As you insert the bumper into the channel with push it up against the end cap to prevent one hand, pull the bumper toward you with...
Page 7
Installation (Cont'd) Boston 2000 Eco Series Boston Series 2000 NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the flexible top to ensure a proper fit. NOTE: Rigid Top: Do not over cut. 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base.
Page 8
Installation (Cont'd) Boston 1000 Series 2b. Rigid Top: Snap the Rigid Top over the Rigid Base. NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the flexible top to ensure a proper fit. NOTE: Rigid Top: Do not over cut. Installation 3.
Plumbing Waste Outlet and P-TRAP off the center of the case to allow use of the P-TRAP pipe section. Never use two water seals in series in The waste outlet is located off the center of the case on any one line. Double P-TRAPS in series will cause a one side allowing drip piping to be run lengthwise under the lock and prevent draining.
Refrigerant Type Refrigerant lines should be sized as shown on the The standard refrigerant will be R-22 unless otherwise refrigeration legend furnished by the store. specified on the customer order. Check the serial plate on Install P-TRAPS (oil traps) at the base of all suction line the case for information.
Electrical Wiring Color Code Field Wiring and Serial Plate Amperage Field Wiring must be sized for component amperes printed on the serial plate. Actual ampere draw may be less than specified. Field wiring from the refrigeration control panel to the merchandisers is required for refrigeration thermostats. Case amperes are listed on the wiring diagram, but always check the serial plate.
Sanitizing solutions will not product. Hussmann cases were not designed to “heat up” harm the interior bottom, however, these solutions should or “cool down” product-but rather to maintain an item’s always be used according to the manufacturer’s directions.
NOT harm the steel’s Copper Coils passive layer. Stainless steel pads can also be The copper coils used in Hussmann merchandisers may used but the scrubbing motion must be in the same be repaired in the field. Materials are available from local direction of the manufacturer’s polishing marks.
Maintenance (Cont'd) frequently to avoid build-up of hard, stubborn stains. If you boil water in your stainless steel equipment, remember the single most likely cause of damage is chlorides in the water. Heating cleaners that contain chlorides has a similar effect. 6.
NOTE: installation instructions and recommendations determining if the refrigerator will be allowed to display provided by Hussmann for the installation potentially hazardous food. For the purpose of this of each individual type refrigerator. evaluation, product temperature above the FDA Food...
Fahrenheit shall be accurate to 1°C (1.8°F). 12. Are the shelf positions, number, and size Temperature measuring devices that are other than recommended by Hussmann? scaled only in Fahrenheit shall be accurate to 13. Is there an improper application or control 2°F.
Page 23
Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling. For further technical information, please log on to http://www.hussmann.com/products/DBP-03.htm...
Page 24
Controller Parameters DBRP PGM0012A01 STANDARD CASE REV A 8/7/17 A tual ( C) A tual ( F) Parameter C o e Default Temperature (set point) roduce (Type I) -50.0°C 50.0°C 2.0°C -2.2 Thermostat Differential 0.1 K 20.0K 2.0 K Max. limitation of setpoint setting -49.0°C 50°C 50.0°C...
Page 25
Controller Parameters (Cont'd) HACCP Actual temperature measurement for the HACCP Last registered peak temperature Selection of function and sensor for the HACCP HACCP function. 1 = S4 used (maybe also S3). 2 = S5 Alarm limit for the HACCP function -50.0°C 50.0°C 8.0°C...
Page 26
August 31, 2018 This warning does not mean that Hussmann products will cause cancer or reproductive harm, or is in violation of any product-safety standards or requirements. As clarified by the California State government, Proposition 65 can be considered more of a ‘right to know’...
Danfoss Controller Operations User Guide Controller for temperature control User Guide AK‐CC 210 Controller for temperature control AK-CC 210 ADAP‐KOOL® Refrigeration control systems ADAP-KOOL® Refrigeration control systems Open Camera IPhone User Hold the camera up to the QR code Android User Open QR Code Reader app if necessary.
Dixell Controller Operations 026-1210 Rev 3 03-FEB-2015 XR75CX Digital Controller for Medium‐Low Temperature Refrigeration Applications Installation and Operation Manual Open Camera IPhone User Hold the camera up to the QR code Android User Open QR Code Reader app if necessary. Hold the camera up to the QR code Tap the notification to be taken to the destination of the QR code...
Page 29
Additional copies of this publication may be obtained by contacting: unit. Hussmann® Chino They can be found on a small metal plate on the unit. 13770 Ramona Avenue • Chino, California 91710 Please note them below for future reference.
Need help?
Do you have a question about the DBP-01 and is the answer not in the manual?