(5)
Service clearance area
The service clearance area, or the sides which must allow access to the IDD for installation or
maintenance, is shown in Figure 4.6.
[Surface P]
• Cable connection
(6)
External magnetic field
The drive should not be installed near the ferromagnetic body like a speaker to avoid the influence of
the external magnetic field.
(7)
Leak magnetic flux
The IDD uses a high performance magnet to achieve a high speed seek. Therefore, a leak magnetic
flux at surface of the IDD is large. Mount the IDD so that the leak magnetic flux does not affect to
near equipment.
C141-E215
[Surface Q]
• Hole for mounting screw
Figure 4.6
Service clearance area
4.1 Mounting Requirements
[Surface R]
• Hole for mounting screw
4-7