5. Installation
1) Unpacking and installation
1. Remove the transport case, tapes and packages. It may fail to run properly if any packaging material
is left on the ice-maker.
2. Take out the accessory box inside and install the leveling feet.
3. Install the ice-maker at the specified place. (See precautions for ice-maker installation position
specified below.)
4. Level the machine with installed leveling feet.
5. Check whether the power supply has the rated voltage. (Please use a leakage protector.)
6. Make sure to use a dedicated properly earthed socket. (Unearthed socket may cause faults and the
danger of electric shock.)
Please install it indoor.
Outdoor installation may cause product damages and poor refrigerating results.
Do not install it where there is hot air.
Install it where there is no heating or heat generating equipment.
Do not install it where ambient temperature goes beyond the range of 10 ° C
~38 ° C.
Do not install it where it is humid or dusty.
.Environmental issues may cause electric leakage which consequently results in
fire and electric shock.
Please install it on smooth and solid ground.
The product will produce vibration and noise on unsmooth ground.
Do not place heavy objects or liquid containing containers
on the ice-maker.
Falling objects and flowing liquids may cause product damages, electric
leakage, etc.
Keep a 30 cm distance between its back and the wall to
facilitate troubleshooting and cooling.
.Inlet/drain pipe close to the wall may lead to faults.