Specifications

Electrical Requirements
IMPORTANT NOTE: Connection of this appliance should
be through a fused connection unit or a suitable isolator,
which complies with national and local safety regulations.
The on/off switch should be easily accessible after the
appliance has been installed. If the switch is not acces-
sible after installation (depending on country) an additional
means of disconnection must be provided for all poles of
the power supply. When switched off, there must be an all
pole contact gap of 3 mm in the isolator switch. This 3 mm
contact disconnect gap must apply to any isolator switch,
fuses, and/or relays according to EN60335.
4 | English
Electrical
Shock
Hazard
Plug power cord directly into a properly
grounded (earthed) outlet.
Do not defeat the grounding (earthing)
nature of the plug.
Do not use adapter or extension cord.
Failure to follow these instructions could
cause serious injury or death.
See installation instructions
Gas Supply
Installation must conform with local codes and ordinances.
Locate the gas supply as shown in the illustrations on
page 6.
The cooktop is equipped for use with natural or liquid
propane (LP) gas. The product rating plate has information
on the type of gas that should be used. For rating plate
location, refer to the illustration below. If this information
does not agree with the type of gas available, check with
the local gas supplier. The gas pressure regulator is built
into the unit. The regulator is set to 10 mbar for natural gas
and 25 mbar for LP.
HEAT OUTPUT
Surface Burner
5.3 kW
Surface Burner
3.5 kW
Surface Burner
2.7 kW
RATING PLATE
Rating plate location
Note -
Apply duplicate Data label to kitchen cabinet
or cupboard door below the cook-top.
The cooktop must be connected to a regulated gas supply.
The supply line must be equipped with an approved
external gas shut-off valve located near the cooktop in an
accessible location. Do not block access to the shut-off
valve. Refer to the illustration below.
A gas supply line of 19 mm rigid pipe must be provided to
the cooktop. If local codes permit, a certified, .9 m long,
13 mm or 19 mm ID flexible metal appliance connector is
recommended to connect the units 1/2" NPT (or ISO 7/1-14)
male inlet to the gas supply line. Pipe joint compounds,
suitable for use with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected
from the gas supply piping system during any pressure
testing of the system at test pressures in excess of 100
(376 g/h)
mbar. The appliance must be isolated from the gas supply
(248 g/h)
piping system by closing its individual manual shut-off
valve during any pressure testing of the system at test
(191 g/h)
pressures equal to or less than 100 mbar.
Wolf natural gas cooktops will function up to 3124 m
in altitude without adjustment and LP gas cooktops will
function up to 2621 m. If the installation exceeds these
elevations, contact your authorized Wolf dealer for a high
altitude conversion kit.
SHUT-OFF VALVE
OPEN POSITION
TO APPLIANCE
GAS SUPPLY
Gas shut-off valve
Note -
For local gas and electrical code
requirements, refer to AS/NZS 5601.1.
TO BE INSTALLED ONLY BY AN
AUTHORIZED PERSON IF CONNECTING TO
FIXED CONSUMER PIPING.