Model: FJ128
Carbon Monoxide Alarm
User Manual

PRODUCT SPECIFICATIONS

• Power Supply: DC 3V(AA 1.5V*2) battery operated
• Sensitivity Setting:
50PPM Between 60 to 90 minutes
100PPM Between 10 to 40 minutes
300PPM Less than 3 minutes
• Standby Current: <20 A (average)
• Alarm Current: <50mA (average)
• Storage/Transport Ambient Condition:
-20~+50℃,10~95% non-condensing
• Sensor Type: electrochemical
• Alarm sound: ≥85dB at 100cm @3.2±0.5KHz pulsing alarm

PRODUCT OVERVIEW

• POWER indicator
The POWER indicator (green LED) is used to indicate power
status of the CO alarm.
The POWER indicator will flash every 33 seconds.
• FAULT indicator
The FAULT indicator (yellow LED) is used to indicate fault or
warning status of the CO alarm.
• ALARM indicator
The ALARM indicator (red LED) is used to indicate alarm
status of the CO alarm.
• TEST/SILENCE button
The TEST/SILECNE button is used to test the unit. Press and
hold to enable TEST function.
• Alarm sounder
The alarm sounder is used to send out CO alarm warning
and fault warning information.
• LCD screen
Indicates CO concentration and alarm status.
MADE IN CHINA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FJ128 and is the answer not in the manual?

Questions and answers

Summary of Contents for ecoey FJ128

  • Page 1 CO alarm. • TEST/SILENCE button The TEST/SILECNE button is used to test the unit. Press and Model: FJ128 hold to enable TEST function. • Alarm sounder The alarm sounder is used to send out CO alarm warning Carbon Monoxide Alarm and fault warning information.
  • Page 2 • CO alarm warning UNDERSTANDING YOUR CO ALARM When the alarm detects a dangerous level of CO, the alarm will emit a loud alarm pattern. The alarm signal pattern is 4 quick beeps followed by 5 seconds of silence. This cycle repeats as •...

Table of Contents