PRODUCT SPECIFICATIONS

• Power Supply: Built-in DC3V(CR123A) Lithium battery
(battery not replaceable)
• Operation Current: <6uA(Standby), <75mA(alarm)
• Alarm Volume: >85dB(A) at 3 meters
• Smoke Sensitivity: 0.094-0.154dB/m
• Heat Sensitivity: 54-70℃
• Silence Time: Approx. 10 minutes
• Product Life: 10 years after manufacture
• Local Smoke Alarm Sound Pattern:
BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s -pause
1.5s, with the red LED flashing, repeat thisalarm pattern.
• Local Heat Alarm Sound Pattern: BI 0.3s - pause 0.1s,
with the red LED flashing,repeat this alarm pattern.
• Comply with standard:
EN14604:2005/AC:2008 BS5446-2:2003.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FJ192 and is the answer not in the manual?

Questions and answers

Summary of Contents for ecoey FJ192

  • Page 1 • Alarm Volume: >85dB(A) at 3 meters • Smoke Sensitivity: 0.094-0.154dB/m • Heat Sensitivity: 54-70℃ • Silence Time: Approx. 10 minutes Model: FJ192 • Product Life: 10 years after manufacture • Local Smoke Alarm Sound Pattern: Smoke and Heat Alarm BI 0.5s - pause 0.5s - BI 0.5s - pause 0.5s - BI 0.5s -pause...
  • Page 2 OPERATION IMPORTANT SAFETY INFORMATION 1. The test button accurately tests smoke alarm functions. Donot • Testing use any other test method.Test smoke alarm weekly toensure Test the unit weekly to ensure proper operation by pressing proper operation. the test button. about 3 seconds later, this will sound the alarm 2.