Control Board (CB) Setting Menu
Category No. Item
Basic
1 Harvest Cycle Termination Temperature
Temperature to complete harvest cycle (detected by
evaporator (cube control) thermistor).
2 Freeze Cycle Termination Temperature
Target integrated value inside control board is
determined by CB Settings 2 and 3. Temperature in
freeze cycle is integrated, and freeze cycle continues
until target integrated value is reached, which
determines dimple diameter setting 2 (medium).
Basically, the smaller CB Setting 2 gets, the larger
integrated value and the smaller dimple diameter
become.
3 Freeze Cycle Termination Time
Target integrated value inside control board is
determined by CB Settings 2 and 3. Time in freeze
cycle is integrated, and freeze cycle continues until
target integrated value is reached, which determines
dimple diameter setting 2 (medium). Basically, the
smaller CB Setting 3 gets, the smaller integrated
value and the larger dimple diameter become.
4 Ambient Temperature Correction Value for Freeze
Cycle Termination
Upper temperature limit to trip control to ensure
minimum dimple size in low temp conditions like at
1°C / wt 5°C.
5 Ambient Temperature Correction Rate for Freeze
Cycle Termination
Percentage of integrated value in low temp
conditions against target integrated value to ensure
minimum dimple size in low temp conditions like at
1°C / wt 5°C based on integrated value inside control
board determined by CB Settings 2 and 3.
6 Freeze Cycle Backup Timer
Timer setting to forcibly terminate freeze cycle if
evaporator (cube control) thermistor cannot sense
freeze cycle termination temp.
7 Dimple Diameter Setting 3 (Large)
Determines dimple diameter for dimple diameter
setting 3 by percentage against target integrated
value. The smaller the setting gets, the larger the
diameter becomes. The larger the setting gets, the
smaller the diameter becomes.
SETTING CHANGE IS INEFFECTIVE.
8 Dimple Diameter Setting 1 (Small)
Determines dimple diameter for dimple diameter
setting 1 by percentage against target integrated
value. The smaller the setting gets, the larger the
diameter becomes. The larger the setting gets, the
smaller the diameter becomes.
SETTING CHANGE IS INEFFECTIVE.
Range
2 to 20°C
(1°C increments)
-5 to -40°C
(0.5°C
increments. The
"." in the lower,
right corner
of the display
indicates .5°C.)
5 to 90 min.
(1 min.
increments)
10 to 50°C
(1°C increments)
10 to 100%
(00=100)
(1% increments)
45 to 90 min.
(5 min.
increments)
50 to 95%
(1% increments)
105 to 130%
(05 to 30
displayed)
(1% increments)
27
Default
Default
(50BAA-Q)
(50BAA-LM)
10
10
-20.5
-29.0
38
47
25
26
85
87
60
90
95
95
105
105