5.7.
Scheduled maintenance table
Maintenance
Daily
Operations
drain condensation
check oil level
clean intake filter
check for oil leaks
check cut-out
replace oil
General cleaning of
compressor
Internal & external
inspection of tank
replace air filter
check tube fittings and
electrical connections

6. TROUBLE SHOOTING

Fault
Pressure drop in the tank.
Pressure switch valve leaks when compressor is idle.
compressor stops and does not restart.
overload switch activated (fig.7).
compressor does not stop at max. pressure.
compressor noisy with metallic knock.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: no liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
fig.6
100 hrs.
200 hrs.
400 hrs.
Air leaks at connections.
non-return valve seal defective.
occasionally the start up load may activate switch.
extension lead too long.
Head unloader not operating (section 4.3.5).
Head gasket or valve fault.
Bearing or piston damage.
Sole UK Distributor, Sealey Group,
Kempson Way, suffolk Business Park,
Bury st. edmunds, suffolk,
IP32 7Ar
Original Language Version
5.8.
IMPORTANT WARNING - Air contaminants taken into the
compressor will affect optimum performance. example: Body
filler dust or paint overspray will clog the pump intake filter and
may cause internal damage to pump/motor components. Please
note that any parts damaged by any type of contamination will
not be covered by warranty.
cause
motor failure.
Pressure switch fault.
filter clogged.
fig.7
Remedy
run compressor to max. pressure, switch off unit.
Brush soap solution over connections and look for
bubbles. tighten connections showing leaks.
If problem persists contact Authorised service Agent.
empty the air tank, remove the non-return valve cap
(fig.6.3) and clean, or if necessary, replace
the seal (fig.6.1).
contact Authorised service Agent.
leave for a few minutes then press the reset button.
remove extension lead and test the compressor by
connecting as near to the main fuse box as possible.
contact Authorised service Agent.
contact Authorised service Agent.
clean or replace filter element.
contact Authorised service Agent.
contact Authorised service Agent.
www.sealey.co.uk
01284 757500
Web
sales@sealey.co.uk
01284 703534
email
sAc10030, sAc05030
RESET TRIP
Issue: 2 - 25/10/11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAc05030 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Sac10030

Table of Contents