LifeTag Installation & Commissioning Guide
Specification
Parameter
Power source
Dimensions (overall)
Ancillary switched output contact rating
Transmitted power (nominal)
Temperature:
Humidity
Base Station to Tag range
Maximum number of Tags per system
Maximum number of Repeater Base Stations
per system
FCC and Industry Canada Information
The LifeTag and LifeTag Base Station comply with US CFR47 part 15 Rules and with IC Standard
RSS210. Operation is subject to the following two conditions: (1) these devices may not cause
harmful interference and (2) these devices must accept interference received, including interference
that may cause undesired operation.
Changes or modifications to these devices not expressly approved in writing by Raymarine could
violate compliance with FCC or IC rules, and void the user's authority to operate the equipment.
Declaration of Conformity
Raymarine UK Ltd. hereby declares that the LifeTag and LifeTag Base Station are in compliance with
the essential requirements and other relevant provisions of the R&TTE Directive 1999/5/EC.
The original Declarations of Conformity may be viewed on the relevant product pages at
www.raymarine.com.
Approvals
EU
USA
Industry Canada
Operating:
Non-operating:
R&TTE Directive 1995/5/EC
FCC Part 15
FCC ID: PJ5-LTB (LifeTag Base Station)
RSP100
ID IC:4069B-LTB (LifeTag Base Station)
Base Station
8 V to 16 V dc external supply
2.6 in x 4.7 in x 1.4 in
(66 mm x 118 mm x 36mm)
200 mA at supply voltage
1 mW
0% to 95% non-condensing
Typically 30 ft (9 m)
Tag
Non-rechargeable, CR2 3V
lithium battery
1.93 in x 2.24 in x 1 in
(49 mm x 56.8 mm x 24.4
mm)
N/A
1 mW
-15°C to +55°C
-20°C to +70°C
16
1
PJ5-LTT (LifeTag)
IC:4069B-LTT (LifeTag)
15