Tycon Power Systems UPSPro UPS-STL48 Quick Start Manual

Backup power system

Advertisement

Wireless Base Stations
Surveillance Cameras
Remote Gate Control
Electric Fence
Up to 200W loads
Congratulations! on your purchase of the UPSPro™ outdoor
backup power system. Please take a moment to review this Qwik
Install Guide before assembly or battery installation.
When following the instructions in this guide take extreme care
to avoid contact with overhead power lines, lights and power circuits.
Contact with power lines, lights or power circuits may be fatal. We rec-
ommend to install no closer than 20 feet to any power lines.
Safety:
For your own protection, follow these safety rules.
Perform as many functions as possible on the ground
Do not attempt to install on a rainy, windy or snowy day or if
there is ice or snow accumulation at the install site or if the
site is wet.
Make sure there are no people, pets, etc. below when you are
working on a roof or ladder.
Recommended Tools: Phillips & Flat Screwdriver,
17/13/10mm wrench, 8mm nut driver
Please help preserve the environment and return
used batteries to an authorized depot
UPSPro™ Backup
DANGER! Avoid Powerlines!
You Can Be Killed!
UPS-STL48
Power System

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UPSPro UPS-STL48 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tycon Power Systems UPSPro UPS-STL48

  • Page 1 UPS-STL48 UPSPro™ Backup Power System Wireless Base Stations ▫ Surveillance Cameras ▫ Remote Gate Control ▫ Electric Fence ▫ Up to 200W loads ▫ Congratulations! on your purchase of the UPSPro™ outdoor backup power system. Please take a moment to review this Qwik Install Guide before assembly or battery installation.
  • Page 2 Qwik Install STEP 1: Prepare the enclosure: Install DIN rail (if required) to door using two phillips head screws. Install just the top mounting bracket to the enclosure using two 8mm bolts. NOTE: It takes two persons to mount the enclosure to a pole. The standard U -Bolt mounting accommodates a pole up to 4”...
  • Page 3 STEP 7: Before attaching the battery cables to the batteries, first remove the battery cable fuse. This will prevent accidental short circuit. Connect the battery cables to the batteries. Connect the Temperature probe from the controller to any of the battery terminals. The tempera- ture sensing lug is just a mechanical connection so it doesn’t matter which terminal it is connected to (+ or -).
  • Page 4 STEP 9: Set the AC/DC power supply input voltage to either 115VAC or 230VAC by moving the screw attached cable to the appro- priate position. WARNING! Make sure this is set correctly before connecting the AC line or you will damage the power supply. STEP 10: Connect the Output + from the power supply to the PV+ position on the large Green connector.
  • Page 5 SPECIFICATIONS Subject to change without notice UPS-STL48-50 UPS-STL48-100 Load Voltage 24V/48V Selectable 24V/48V Selectable Max Load 200W 200W VAC Input +/- 10% 115 / 230VAC user selectable VAC Input Current 12A @ 115VAC ; 6A @ 230VAC Max Battery Capacity 200Ah 400Ah Battery Type...
  • Page 6 5. BATTERY MAINTENANCE: The batteries used in the UPSPro sys- tems don’t require any maintenance. They should last up to 5 years in normal use. Note: Never store batteries for any length of time in a dis- charged state or it will kill the battery. 6.
  • Page 8 8000050 Rev 1 UPS-STL UPSPro™ Qwik Install Guide...

Table of Contents