Installation Requirements - Rohl PERRIN ROWE G1655 Installation Sheet

Hot water dispenser collection for use only with perrin and rowe hot water tank
Hide thumbs Also See for PERRIN ROWE G1655:
Table of Contents

Advertisement

INSTALLATION REQUIREMENTS

Electrical Requirements
A standard 120v electrical outlet is required under the sink. If possible, use a separate circuit dedicated to your Hot
Tank. It is recommended that a separate circuit serving only your electronic instant hot water appliance be provided
or use an outlet that can be turned on/off by a switch. This electronic instant hot water appliance is equipped with a
power supply cord with a power plug. To minimise possible shock hazard, the cord must be plugged into mating,
ground-type outlet, grounded in accordance with all national and local codes and ordinances. If a socket outlet is not
available, it is the responsibility and obligation of the customer to have a properly grounded outlet installed by a
qualified electrician.
Water Supply Requirements
If local codes permit, the instant hot water Dispenser feed line should be connected to the hot and cold water supply
line using an isolation valve or another means for providing the hot and cold water to the Dispenser. IMPORTANT: If
local codes do not permit the use of isolation valves, special feed valves can be obtained from your local plumbing
supply distributor. f the water is mixed with impurity, ironing chips, grains of sand, and so on, the pipes of the electron-
ic instant hot water appliance and Dispenser will be blocked and will void the guarantee.
Environment requirement
Don't install the electronic instant hot water appliance outdoors or in a location that may fall below 32F, otherwise the
pipes and the Dispenser and tank will be frozen and there will be serious safety trouble, possible bodily -injury, acci-
dents and damaged caused and the guarantee will be void. It's forbidden to wash the electronic instant hot water
appliance with water directly. The installation environment should be ventilated, with protection from the direct sun-
shine. When installing the electronic instant hot water appliance, provide approximately 10cm to 15cm (4 - 5 ½") of air
space on the sides of the unit for air circulation and approximately 2.5cm (1") from the mounting wall. The environ-
ment humidity should be in the range of 10% to 60%. Be sure there is no dew.
Instant Hot Water Dispenser Information
Connecting a standard Dispenser may cause injury and will damage the electronic instant hot water appliance and void
the guarantee. Due to high water temperature, and for safety reasons, the electronic instant hot water appliance is not
under pressure.
Instant Hot Water Appliance Temperature Adjustment
For temperatures above 203F:- it has been set for optimum performance in most common and typical known installa-
tions. However there are factors which may influence the performance of the instant hot water appliance such as
incoming water temperature, atmospheric pressure and altitude. Should you experience any discharge of water from
the spout during heat up, you can reduce the setting to compensate for this by 3F degrees at a time. If in doubt please
ask your dealer for further guidance.