06/2005
Mod: E65/PR4T-230-3
Production code: 65/40 FTRE
The catering program

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E65/PR4T-230-3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Diamond E65/PR4T-230-3

  • Page 1 06/2005 Mod: E65/PR4T-230-3 Production code: 65/40 FTRE The catering program...
  • Page 2 INDEX Paragraph Installation instructions Compliance with EEC directives Installation drawings Wiring diagrams Electrical specifications Technical data Preliminary installation instructions Regulations, technical rules and general specifications Installation 2.2.1 Electrical connection 2.2.1.1 Equipotential Paragraph User instructions Start-up Operating Instructions - Start-up and switching-off Maintenance, cleaning and care “CE”...
  • Page 3: Installation Instructions

    INSTALLATION INSTRUCTIONS CONFORMITY WITH EEC DIRECTIVES REMARK: The electric fry tops are made in compliance with the basic requirements envisaged by EEC directives, in accordance with “EEC Directive 73/23 on low voltage”, “EEC Directive 89/336 on electromagnetic compatibility” and are marked “CE” according to the EEC Directive 93/68.
  • Page 4 ELECTRICAL SPECIFICATIONS: 65/70FTE-CR 65/70 FTE 65/40 FTE-CR 65/40 FTE 65/70 FTRE-CR 65/70 FTRE 65/40 FTRE-CR Model 65/40 FTRE 65/70 FTRRE 65/70 FTES 65/40 FTES 65/70 FTRRE-CR Rated voltage 400V – 3N~ Total power kW Power cable H05RN-F H05RN-F H05RN-F H05RN-F Cross section 5 x 1,0 mm 5 x 1,5 mm...
  • Page 5 70/70 FTE 70/40 FTE 70/70 FTE-CR 70/70 FTRE 70/40 FTE-CR 70/40 FTRE 70/70 FTRE-CR Model 70/70 FTRRE 70/40 FTRE-CR 70/40 FTES 70/70 FTRRE-CR 70/70 FTES Rated voltage 400V – 3N~ Total power kW Power cable H05RN-F H05RN-F H05RN-F H05RN-F Cross section 5 x 1,0 mm 5 x 1,5 mm 5 x 1,0 mm...
  • Page 6 110/90 FTE 110/90 FTE-CR 110/50 FTE 110/50 FTE-CR 110/90 FTRE 110/90 FTRE-CR 110/50 FTRE 110/50 FTRE-CR Model 110/90 FTRRE 110/90 FTRRE-CR 400V – 3N~ Rated voltage Total power kW 13,2 13,2 Power cable H05RN-F H05RN-F H05RN-F H05RN-F Cross section 5 x 1,5 mm 5 x 1,5 mm 5 x 2,5 mm 5 x 2,5 mm...
  • Page 7 PRELIMINARY INSTALLATION INSTRUCTIONS The fry-top must be positioned in a well-aired room, if possible under a hood to remove cooking steam thoroughly. Before starting the appliance, remove all protective film; thoroughly clean the surfaces with a soft cloth, lukewarm water and detergent, so as to remove all anti-rust products applied during the manufacturing stage, then dry with a clean cloth.
  • Page 8 2.2.1 Electrical connection 1) The electric fry tops are designed to operate off 400 VAC+3N voltage. 2) The connection to the mains must be carried out through a suitably rated trip switch which has at least 3 mm between the contacts. Moreover, the mains voltage - when the appliance is working - must not exceed 10% of the voltage value.
  • Page 9: Putting Into Operation

    USERS’ OPERATING INSTRUCTIONS PUTTING INTO OPERATION Fy tops are appliances designed for cooking food and should be exclusively used by trained personnel following these operating instructions. Any other use of the appliance is to be considered improper and therefore dangerous. You are advised to clean carefully the griddle plates before using them for the first time.
  • Page 10: Maintenance, Cleaning And Care

    MAINTENANCE, CLEANING AND CARE Before carrying out any cleaning operations disconnect the power at the mains. It is recommended that the installation be checked by an authorised technician at least twice a year. For the daily cleaning of the appliance, remove the grease drawer, empty it, remove with a stripping knife or with a damp cloth the residual food and clean it carefully.