Summary of Contents for Heylo PV 4200 EX

  • Page 1 Stand: 04/2016 Art.-Nr. 1 110 810 DER EXPERTE FÜR PROFIS PV 4200 EX VENTILATOR BEDIENUNGSANLEITUNG USER MANUAL Ventilator Ventilator...
  • Page 2: Table Of Contents

    Type: EFI75XX HEYLO GmbH of Im Finigen 9, D-28832 Achim, Germany, declares that, if they are fitted, maintained and used in conformity with the operating instructions and the generally accepted engineering standards, the machines mentioned are in keeping with the fundamental safety and health requirements. In case of unauthorised changes of the machine, the directives shall forfeit their validity.
  • Page 3: Safety Guidelines

    Keep away from children: Do not allow children to play with or in the vicinity of the unit. Electric connection: HEYLO PowerVent 4200 EX has been designed for operation at 115 / 230 V and 50 / 60 Hz. In explosive atmospheres, the device may be operated only with attached special plug.
  • Page 4: Possible Application

    (2) Possible application In potentially explosive environments, transport ventilator PowerVent 4200 EX is the right choice. It draws off dangerous gases safely and quickly. The housing made of a robust ABS carbon plastic passes voltage into the floor and thus prevents static charges and for this reason dangerous sparking. The housing and motor sealing is in keeping with the high protection class IP65 and offers an effective protection against dust and water.
  • Page 5: Information On Ex-Proof Applications

    Special features in explosion-proof areas:  Installation conditions and different hazardous areas have to be observed.  Connect device to explosion-proof power socket only.  Only use antistatic air hoses and ground them, when required. Accessories Please use suitable accessories only ! For use in non-explosive areas you can use the following accessories: 1450290 Connection adapter from 230 CEE to 230 V shockproof plug...
  • Page 6 Explosion protection | Classification Explosion groups, temperature classes If the device group and the device category is used to determine, in which zone an apparatus may be used, the explosion group and the temperature class determines, for which media the apparatus may be used within the zones.
  • Page 7: Maintenance / Repair

    If and when necessary remove and repair the damaged cable. Do not take the air mover apart for maintenance purposes. The air mover is maintenance-free. Replace the special screws and washers as well as parts of the air mover by original HEYLO spares parts exclusively.
  • Page 8: Fault Finding

    Unbalance of the impeller. Balance or replace the impeller. Impeller is bent. Replace impeller. Motor shaft is bent. Replace motor. B = user / HS = HEYLO service Ask your local dealer for spare parts or get in touch with HEYLO service department.
  • Page 9: Wiring Diagram

    (8) Wiring diagram...
  • Page 10: List Of Spare Parts

    (9) List of spare parts HEYLO Item Art. No. Description 1761050 ATEX MOTOR 1761051 Fan wheel 1761052 Washer / 1/2" 1761053 Safety splint 1761054 Washer / 7/16" 1761055 1761056 Housing 1761057 Hose connection socket / 12"/30 cm 1761058 Cast adapter...