TPC Coupler
For your own safety, please read this leaflet carefully before you
initially start-up. You can find the latest update online.
Safety Instructions
This product has left our premises in absolutely perfect condition. In
order to maintain this condition and to ensure a safe operation, it is
absolutely necessary for the user to follow the safety instructions
and warning notes written in this user manual. Damages caused by
the disregard of this user manual are not subject to warranty. The
dealer will not accept liability for any resulting defects or problems.
If the product will be operated in any way different to the one
described in this manual, it may suffer damages and the guarantee
becomes void. Furthermore, any other operation may lead to
dangers like crash etc. Please consider that unauthorized
modifications on the adapter are forbidden due to safety reasons.
Operating Determinations
This coupler is designed for installing projectors, lighting effects etc.
on a truss system. The maximum load must never be exceeded.
This product is designed for professional use, e.g. on stages, in
discotheques, theatres etc. Make sure that the area below the
installation place is blocked when rigging, derigging or servicing.
Installation Instructions
DANGER TO LIFE! Please consider the DIN 15922 and the
respective national norms during the installation! The
installation must only be carried out by an authorized dealer!
Before taking into operation for the first time, the installation
has to be approved by an expert.
• The installation of the device has to be built and constructed in a
way that it can hold 10 times the weight for 1 hour without any
harming deformation.
• The installation must always be secured with a secondary safety
attachment, e.g. an appropriate catch net. This secondary safety
attachment must be constructed in a way that no part of the
installation can fall down if the main attachment fails.
• When rigging, derigging or servicing the device staying in the area
below the installation place, on bridges, under high working places
and other endangered areas is forbidden.
• The operator has to make sure that safety-relating and machine-
technical installations are approved by: a) an expert before taking
into operation for the first time and after changes before taking
into operation another time. b) an expert after every four year in
the course of an acceptance test. c) a skilled person once a year.
• The device should be installed outside areas where persons may
walk by or be seated.
• The device has to be installed out of the reach of people.
• Overhead rigging requires extensive experience, including (but not
limited to) calculating working load limits, installation material
being used, and periodic safety inspection of all installation
material and the device. If you lack these qualifications, do not
attempt the installation yourself, but instead use a professional
structural rigger. Improper installation can result in bodily injury
and or damage to property.
• Devices in hanging installations may cause severe injuries when
crashing down! If you have doubts concerning the safety of a
possible installation, do not install the device!
• Before rigging make sure that the installation area can hold a
minimum point load of 10 times the device's weight.
• For overhead use, always install an appropriate safety bond. You
must only use safety bonds complying with DIN 56927, quick links
complying with DIN 56926, shackles complying with DIN EN 1677-
1 and BGV C1 carbines. The safety bonds, quick links, shackles
and the carbines must be sufficiently dimensioned and used
correctly in accordance with the latest industrial safety regulations
(e. g. BGV C1, BGI 810-3).
• The maximum drop distance must never exceed 20 cm. A safety
rope which already hold the strain of a crash or which is defective
must not be used again.
Eurolite is a brand of Steinigke Showtechnic GmbH I Andreas-Bauer-Str. 5 I 97297 Waldbüttelbrunn Germany
• For overhead rigging in public or industrial areas, a series of
safety instructions have to be followed that this manual can only
give in part. The operator must therefore inform himself on the
current safety instructions and consider them. The manufacturer
cannot be made liable for damages caused by incorrect
installations or insufficient safety precautions!
Maintenance
• The operator has to make sure that safety-relating and machine-
technical installations are inspected by: a) an expert after every
four years in the course of an acceptance test. b) a skilled person
once a year. The following points have to be considered during
the inspection: a) All screws used for installing the devices or
parts of the device have to be tightly connected and must not be
corroded. b) There must not be any deformations on housings,
fixations and installation spots (ceiling, suspension, trussing).
• Observe prescribed testing deadlines: a) Once a year by an
expert. b) Every four years by a skilled person. c) Before every
use for breakage and function by the operator.
• Should you have further questions, please contact your dealer.
Technical Specifications
Item
TPC-10 59006856, 59006858
TPC-15 5900685E, 5900685F
TPC-20 59006859
TPC-30 59006860, 59006862
TPC-31 59006865, 59006867
TPC-32 59006868
TPC-35 59006870, 59006872
TPC-36 5900687A
TPC-50/35 59006925
TPC-50 59006800, 59006802
TPC-51 59006848, 59006849
TPC-55 59006845, 59006846
TPC-56 59006850, 59006930
TPC-56Q 59006851, 59006931
Every information is subject to change without prior notice. © 15.11.2018
D00120673, version 4
Max. load
Weight
Ø Tube
WLL (4-fold)
150 kg
0.3 kg
50 mm
150 kg
0.3 kg
50 mm
10 kg
0.03 kg
20 mm
500 kg
0.5 kg
50 mm
500 kg
0.6 kg
50 mm
200 kg
0.4 kg
50 mm
500 kg
0.9 kg
50 mm
200 kg
0.5 kg
50 mm
150 kg
0.2 kg
35/50 mm
800 kg
0.7 kg
50 mm
800 kg
0.8 kg
50 mm
800 kg
1.3 kg
50 mm
500 kg
0.7 kg
50 mm
500 kg
0.7 kg
50 mm