Download Print this page

Advertisement

Quick Links

MS2000X
User Information
The MS2000X is an Emergency Signaling Monitoring System for Grace's worker safety
®
®
®
products including SuperCELL
, LTX200, and TPASS
, WorkForce
and others. The MS2000X
has several enhanced features including a simple interface to existing security and alarm
systems. The MX2000X contains an optional audible horn and strobe light, activated upon
receiving emergency alarm signals from Grace worker-safety devices.

Advertisement

loading
Need help?

Need help?

Do you have a question about the MS2000X and is the answer not in the manual?

Questions and answers

Summary of Contents for Grace MS2000X

  • Page 1 MS2000X User Information The MS2000X is an Emergency Signaling Monitoring System for Grace’s worker safety ® ® ® products including SuperCELL , LTX200, and TPASS , WorkForce and others. The MS2000X has several enhanced features including a simple interface to existing security and alarm systems.
  • Page 2 The MS2000X must be mounted in an area where stranded wire from 14-22AWG. Wire should be there is a clear, unobstructed path to the environ- stripped at a 1/2”. Wires should be inserted by us- ment where the SuperCELL (man-down alarm) or ing a small screwdriver to depress the lever and ®...
  • Page 3 Inside View of MS2000X with -AC, -B, -LS, and -D Options Installed Additional Notes: • Except for the battery, all parts of the MS2000X are attached to the PCB. • Connect the AC Power cable to the Line, Neutral, and Ground positions.
  • Page 4 5 ON and 6 ON = High 5 ON and 6 OFF = Mid 5 OFF and 6 OFF = Low 7 ON and 8 ON = Horn ON 7 OFF and 8 OFF = Horn OFF Page 4 MS2000X-H UI 1019...
  • Page 5 Frequency Range: 902-928 MHz (frequency hopping spread spectrum) FCC ID: J5MXHEM -- Meets FCC Part 15 IC: 5916A-MXHEM -- Complies with Canadian ICES-003 For Use With: Grace Telemetry Systems using the RadioH platform (SuperCELL , LTX200, TPASS , WorkForce ®...
  • Page 6 - PM2040 Mounting Assembly - Pole Mounted with ‘C’ Brackets - Bolts and Bracket Flat Washer Bracket Assembly Bolt Toothed Bracket Washer Clamp Pole Non-Metallic Pole Non-Metallic Bolts and Bracket Assembly Improper Installation May Degrade Performance Page 6 MS2000X-H UI 1019...
  • Page 7 OPTIONAL 8-Pin Connector p/n: MS-D OPTIONAL 10 Foot Cable with Connector OPTIONAL PHONE DIALER p/n: MS-CA-10 p/n: ATD MS2000X with phone dialer has 8 pin connector to supply relay contact trigger and power to the external phone dialer. Wiring Pin 1 GREEN...
  • Page 8 This warranty is valid only when the returned products are accompanied by a sales slip or other proof of purchase that states the date and location of purchase. Grace Industries, Inc. will not repair or replace any merchandise under warranty which has been damaged because of accident, misuse or abuse of the products while in pos- session or control of the consumer.
  • Page 9 • Location: Tracking the location of the SuperCELL® is • Device Run Time: Approximately 40 hrs. in Sensing possible when used in conjunction with the Grace Mode, and 10 hrs. in Alarm Mode. Locator Beacon and Grace-Watch® safety monitoring •...
  • Page 10 ALARM MONITORING: Alerts the Lone Worker that a battery is either too hot or cold, or has a fault. GRACE Man-Down telemetry device, within signaling Charging is complete when the Green charge LED range, is transmitting an alarm message. This alert can starts to slowly fl ash.
  • Page 11 The Alarm History Display page displays the name SuperCELL® into Setup Mode, where the various user and unit ID of any Grace Industries telemetry product preferences of the device can be changed. that has transmitted an alarm message received by To enter Setup Mode, proceed to the Setup Mode the SuperCELL®.
  • Page 12 # to increase (or decrease) the display contrast by 10. Pressing MENU/PWR will navigate away from the View Adjust page. Resetting the device will exit out of Setup Mode and return the SuperCELL® to the home page. IrDA Transfer Mode allows the SuperCELL® device Grace Industries, Inc.
  • Page 13 L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Grace Industries, Inc.
  • Page 14 Icon Line: The Icon Line is the display line at the top of the factory this number will usually be 9090. home page that displays the device status icons. Man-Down Alarm Mode: A SuperCELL® , or other GRACE Industries telemetry device, enters Man-Down Alarm Mode when the Motion Sensing Timer counts down to zero.
  • Page 15 This warranty is void if any attempt to repair or replace parts was made or attempted by other than qualifi ed Grace Industries, Inc. personnel. This warranty is void if any of the sealed compartments are opened or tampered with. Send all returned merchandise, prepaid and accompanied by proof of purchase to: Grace Industries, Inc., Repair Division,...
  • Page 16 305 Bend Hill Road, Fredonia, PA 16124 USA www.graceindustries.com (724)-962-9231 Grace Industries, Inc.
  • Page 17 • Location: Tracking the location of the SuperCELL® is • Device Run Time: Approximately 40 hrs. in Sensing possible when used in conjunction with the Grace Mode, and 10 hrs. in Alarm Mode. Locator Beacon and Grace-Watch® safety monitoring •...
  • Page 18 ALARM MONITORING: Alerts the Supervisor that a does not turn on or a Red LED turns on, then the bat- GRACE Man-Down telemetry device, within signaling tery is either too hot or cold, or has a fault. range, is transmitting an alarm message. This alert can Charging is complete when the Green charge LED be cleared from the SuperCELL®...
  • Page 19 The Alarm History Display page displays the name SuperCELL® into Setup Mode, where the various user and unit ID of any Grace Industries telemetry product preferences of the device can be changed. that has transmitted an alarm message received by To enter Setup Mode, proceed to the Setup Mode the SuperCELL®.
  • Page 20 Setup Mode Page 4 - View Adjust device. The middle text line displays the CPU fi rmware version found on the device. The Bottom text line displays the creation date of this The View Adjust page allows the display contrast fi rmware version. Grace Industries, Inc.
  • Page 21 Upon When Sound is enabled, the Sound Icon appears entering Alarm Mode, the SuperCELL® will sound a solid; when Sound is disabled, the Sound Icon repeating alarm tone and transmit alarm messages. appears empty. Grace Industries, Inc.
  • Page 22 The Inhibit Timer page allows the Alarm Inhibit the MENU/PWR button. At the AlarmVibConstant Timer to be enabled or disabled. page, the SEL/PWR button enables or disables the The SuperCELL® is shipped with the Alarm Inhibit Constant Alarm Vibration setting. Timer enabled. Grace Industries, Inc.
  • Page 23 L’exploitation est autorisée aux deux conditions suivant- es : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Grace Industries, Inc.
  • Page 24 This warranty gives you specifi c legal rights and you may also have other rights qualifi ed Grace Industries, Inc. personnel. This warranty is void if any of the sealed which may vary from state to state.
  • Page 25 TPASS 3 while ® in possession or control of the consumer or outside of Grace AVERTISSEMENT! Les changements ou modifi cations non Industries Inc’s control. This warranty is void if any attempt to expressément approuvés par la partie responsable de la con-...
  • Page 26 ● When in Alarm, reset to Sensing Mode by simul- Dimensions: 2-1/8” wide, by 2-1/4” deep (with clip), TPASS 3 may be used for personnel Safety Monitoring when used with Grace Advanced Safety Monitoring Systems ® taneously pressing both side buttons.