Rheem 800 Series Owner's Manual page 15

Gas domestic indoor water heater
Table of Contents

Advertisement

MINOR MAINTENANCE EVERY SIX MONTHS
It is recommended minor maintenance be performed every six (6) months. Minor
maintenance can be performed by the dwelling occupant.
The minor maintenance includes:
Operate the easing lever on the temperature pressure relief valve. It is very
important you raise and lower the lever gently. Refer to
Pressure Relief Valve"
Warning: Exercise care to avoid any splashing of water, as water
discharged from the drain line will be hot. Stand clear of the drain line's point
of discharge when operating the valve's lever.
Operate the easing lever on the expansion control valve (if fitted). It is very
important you raise and lower the lever gently. Refer to
Valve"
on page 15.
Check the drain line from the safe tray (if one is installed) is not blocked.
EXPANSION CONTROL VALVE
In many areas, including South Australia, Western Australia and scaling water
areas, it is mandatory an expansion control valve is fitted to the cold water line
to the water heater. The expansion control valve may discharge a small quantity
of water from its drain line during the heating period instead of the temperature
pressure relief valve on the water heater.
Operate the easing lever on the expansion control valve once every six (6)
"Minor Maintenance Every Six Months"
months. Refer to
important the lever is raised and lowered gently. If water does not flow freely
from the drain line when the lever is lifted, then the water heater should be
checked by Rheem Service or their nearest Accredited Service Agent. The
expansion control valve should be checked for performance or replaced at
intervals not exceeding five (5) years, or more frequently in areas where there is
a high incidence of water deposits.
on page 16.
15
MAINTENANCE REQUIREMENTS
"Temperature
"Expansion Control
on page 15. It is very