Climer ECOHEAT TD EH260TDSH4 Installation And User Manual

Climer ECOHEAT TD EH260TDSH4 Installation And User Manual

Advertisement

INSTALLATION AND USER MANUAL
ECOHEAT TD
EH260TDSH4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ECOHEAT TD EH260TDSH4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Climer ECOHEAT TD EH260TDSH4

  • Page 1 INSTALLATION AND USER MANUAL ECOHEAT TD EH260TDSH4...
  • Page 2 INSTALLATION AND USER MANUAL ECOHEAT TD V0REV1EN0422...
  • Page 3: Table Of Contents

    INSTALLATION AND USER MANUAL ECOHEAT TD INTRODUCTION ......................1 GENERAL INDICATIONS .....................1 TECHNICAL INFORMATION ..................3 INSTALLATION STEPS ....................5 THERMODYNAMIC SOLAR PANEL INSTALLATION ...........7 PLACING ECOHEAT ......................8 CONNECTION BETWEEN ECOHEAT TD AND PANELS ........9 HIDRAULIC CONNECTION ..................12 ELECTRICAL CONNECTION ..................13 COMISSIONING.
  • Page 4: Introduction

    INSTALLATION AND USER MANUAL ECOHEAT TD 1. INTRODUCTION This product, has been manufactured according to the European Quality Standards, incorporates prime grade materials and its correct working has been tested before it leaves our facilities. Through this Installation and User Manual, you will be guide towards the correct and safety installation of the product.
  • Page 5 INSTALLATION AND USER MANUAL ECOHEAT TD 2.3. Package contents The ECOHEAT system comprises the following components: - Thermodynamic panel - Anchoring elements - ECOHEAT TD - Silent-Blocks - User Manual 2.4. Indications about transport and unpacking the unit The unit is supplied packed into a wooden pallet properly secured to prevent damage during transport.
  • Page 6: Technical Information

    INSTALLATION AND USER MANUAL ECOHEAT TD 3. TECHNICAL INFORMATION 3.1. Operating Principle Figure 1. Operating principle 3.2. Dimension drawings It is possible to remove the side and front casing access easily to any part of the system. Figure 2. Exploded view V0REV1EN0422...
  • Page 7 INSTALLATION AND USER MANUAL ECOHEAT TD Figure 3. Dimensions, mm Figure 4. Back connections Figura 5. Front connections Power supply 230 V/1ph/50 Hz Temperature pocket (Boiler temperature probe) Condesate drain Coil outlet, ¾’’ Refrigerant inlet (gas), 1/2‘’ Coil inlet, ¾’’ Refrigerant outlet (liquid), 3/8”...
  • Page 8: Installation Steps

    INSTALLATION AND USER MANUAL ECOHEAT TD 3.3. Technical data Model EH260TDSH4 Cylinder Capacity, L Maximum operating pressure, bar Heat pump data Energy Efficiency Class Load profile Heating capacity range *, W 2860 - 5120 Input power range *, W 900 - 1120 Maximum temp.
  • Page 9 INSTALLATION AND USER MANUAL ECOHEAT TD - Pipe expander - Welder - Copper Rods (40 % Silver) - Insulating hose - Drill - Screwdriver - Hydraulic installation components - Electric installation components Once it has been checked that it is available all the necessary components and tools, the installer should follow the next steps: 1.
  • Page 10: Thermodynamic Solar Panel Installation

    INSTALLATION AND USER MANUAL ECOHEAT TD THERMODYNAMIC SOLAR PANEL INSTALLATION 5.1. Site selection The choice of the installation site of the thermodynamic panel is a key factor in the final performance of the unit. For this reason, we recommend following the indications in order to achieve the best performance: - South orientation is indeed the best to take the maximum advantage of solar radiation.
  • Page 11: Placing Ecoheat

    INSTALLATION AND USER MANUAL ECOHEAT TD 5.2. Anchoring panel Beside the panel, it is supplied a bag with anchoring elements that contains the following pieces: - 6 x Aluminium support (L shape) - 6 x Screws M5 - 12 x Nuts M5 - 18 x Washer 5 - 18 x Sheet Metal Screws - 18 x Blocks M6...
  • Page 12: Connection Between Ecoheat Td And Panels

    INSTALLATION AND USER MANUAL ECOHEAT TD 7. CONNECTION BETWEEN ECOHEAT TD AND PANELS Pipeline installation First, measure the distance between Ecoheat and Panels and cut the appropriate copper pipe length. The diameter for each line is: - Liquid line: 3/8 inch - Gas line: 1/2 inch b.
  • Page 13 INSTALLATION AND USER MANUAL ECOHEAT TD IMPORTANT: It is recommended to weld pipelines by oxyacetylene welding. Welding is a critical step in the installation and to do it well ensures that the system will run properly along its useful life. Only expert staff should make this step by using proper tools and high-quality materials.
  • Page 14 INSTALLATION AND USER MANUAL ECOHEAT TD Join refrigerant pipes to the Panels and Ecoheat Panels are supplied with two nuts for the inlet and outlet connection. The inlet to each panel is 1/4 inch diameter. The installer has to insert the nut into the copper pipe, flare the pipe and then use the nut to fit it.
  • Page 15: Hidraulic Connection

    INSTALLATION AND USER MANUAL ECOHEAT TD HIDRAULIC CONNECTION The hydraulic connections are shown in the following scheme: The installer must install the following components of the hydraulic circuit shown in the scheme. - Cold water inlet (1) - Ball valves (2) - Pressure reducing valve (3) - Non-return valve (4) - Lined Filter Strainer (Y Type) (5)
  • Page 16: Electrical Connection

    INSTALLATION AND USER MANUAL ECOHEAT TD 9. ELECTRICAL CONNECTION The power supply of the system is 230/1/50 Hz. The power supply line must be protected with a 16 A circuit breaker. The electrical scheme is shown in the picture below: PV: Photovoltaic connection LPS: Low pressure switch HPS: High pressure switch...
  • Page 17: Comissioning. Controller

    INSTALLATION AND USER MANUAL ECOHEAT TD 10. COMISSIONING. CONTROLLER. 10.1. USER INTERFACE DESCRIPTION E S C R I P T I Symbol Meaning when it lights Compressor switched on Defrost active Fan switched on Alarm active Compressor working hours exceeded Unit in ºC Unit in ºF Electric heater switched on...
  • Page 18 INSTALLATION AND USER MANUAL ECOHEAT TD 10.2. INSTALLATION- Switching on After full installation of the water heater (power and water pipes connected) and after the water heater tank is full of water, power can be turn ON. 1. After filling the tank of water, connect the mains plug to the mains supply.
  • Page 19 INSTALLATION AND USER MANUAL ECOHEAT TD 10.4. Unlocking the keypad When 30 have elapsed without the keys being pressed, the display will show the ‘’ LOC’’ label and the keypad will lock automatically Touch any key until the screen shows UnL, to unlock the keypad 10.5.
  • Page 20 INSTALLATION AND USER MANUAL ECOHEAT TD 10.6. Changing operating mode To change the operating mode, touch the key for 4 seconds. The screen will show blinking the selectable operating modes. Use the keys to select the operating mode. Touch to confirm or to cancel The screen will show again the water temperature...
  • Page 21 INSTALLATION AND USER MANUAL ECOHEAT TD 10.7. ECO Mode ECO mode: Maximum savings. The system heats water only by heat pump technology. This is the factory default mode. Setting the ECO temperature setpoint The water temperature set point in ECO mode can be changed with the SP1 parameter. Touch key and select SP1.
  • Page 22 INSTALLATION AND USER MANUAL ECOHEAT TD 10.8. AUTO Mode It maintains a steady temperature by the heat pump and only use the electrical heater if the temperature falls drastically. Setting the AUTO temperature setpoint The water temperature set point in AUTO mode can be changed with the SP2 parameter. Touch key and select SP2.
  • Page 23 INSTALLATION AND USER MANUAL ECOHEAT TD 10.9. OVERBOOST Mode Select this mode to achieve a fast heating by using simultaneously heat pump and electric heater. This mode Works as a rapid heating. Once the setpoint temperature is reached, the system returns to the initial mode.
  • Page 24 INSTALLATION AND USER MANUAL ECOHEAT TD Parameter SP3 allows to set the minimum temperature that Overboost can be actived. To change it value, follow the procedure: Touch and select with SP3. Touch to confirm The display will show the programmed temperature Touch to select the...
  • Page 25 INSTALLATION AND USER MANUAL ECOHEAT TD 10.10. PHOTOVOLTAIC INPUT Working on this mode, the system automatically heats the water due to electric energy surplus or by Off Peak rate. The parameters of this mode can only be changed by the Installer’s Menu. Contact with the technician for more information.
  • Page 26 INSTALLATION AND USER MANUAL ECOHEAT TD 10.12. Antilegionella The anti-legionella feature reduces the risk of development of bacteria in the tank. The system performs a thermal shock disinfection to avoid any risk conditions that might cause the development of bacteria. The disinfection is made automatically once a month, reaching a temperature of 70 ºC.
  • Page 27: Warranty Conditions

    INSTALLATION AND USER MANUAL ECOHEAT TD 11. WARRANTY CONDITIONS Component Warranty period Stainless steel tank, Stain steel 2205 5 years Electrical, electronic and mechanical removable components 2 years Evaporator panel 5 years WARRANTY CONDITIONS The warranty exclusively covers productions faults of the product, excluding any liability for any material damage or injury that results directly or indirectly from the use of this product.