ADJ JOLT BAR FX User Manual
Hide thumbs Also See for JOLT BAR FX:

Advertisement

Quick Links

JOLT BAR FX
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JOLT BAR FX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADJ JOLT BAR FX

  • Page 1 JOLT BAR FX User Manual...
  • Page 2 ©2023 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
  • Page 3: Table Of Contents

    C O N T E N T S Introduction Limited Warranty (USA Only) Warranty Registration | Features Safety Guidelines Overview Installation Remove Device Management Control Panel System Menu DMX Setup DMX Traits LED Pixel Zones Color Macro Chart Dimmer Modes and Curves Daisy Chain Power Linking | Cleaning and Maintenance Dimensional Drawings Specifications...
  • Page 4: Introduction

    BOX CONTENTS Omega Brackets 1.83M locking power cable CUSTOMER SUPPORT Contact ADJ Service for any product related service and support needs. Also visit forums.adj.com with questions, comments or suggestions. ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST 323-582-2650 | Fax: 323-832-2941 | support@adj.com...
  • Page 5: Limited Warranty (Usa Only)

    All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package. No accessories should be shipped with the product.
  • Page 6: Warranty Registration | Features

    WA R R A N T Y R E G I S T R AT I O N The Jolt Bar FX carries a 2 year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items, whether under warranty or not, must be freight pre-paid and accompanied by a return authorization (R.A.) number.
  • Page 7: Safety Guidelines

    THIS FIXTURE IS COMPOSED OF SOPHISTICATED ELECTRONIC COMPONENTS. TO GUARANTEE SMOOTH OPERATION, IT IS IMPORTANT TO FOLLOW ALL INSTRUCTIONS AND GUIDELINES IN THIS MANUAL. ADJ PRODUCTS, LLC IS NOT RESPONSIBLE FOR INJURY AND/OR DAMAGES RESULTING FROM THE MISUSE OF THIS FIXTURE DUE TO THE DISREGARD OF THE INFORMATION PRINTED IN THIS MANUAL.
  • Page 8: Overview

    O V E R V I E W Mounting Bracket Bracket Adjustment Knobs Power Safety Cable Loop Firmware Upgrade Slot Control Panel Safety Cable Power Loop Bracket Adjustment Knobs Mounting Bracket Power...
  • Page 9: Installation

    I N S TA L L AT I O N FLAMMABLE MATERIAL WARNING Keep fixture minimum 8.5 in. (22cm) away from flammable materials and/or pyrotechnics. ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations. MINIMUM DISTANCE TO OBJECTS/SURFACES IS 1.6 FEET (0.5 METERS). MINIMUM DISTANCE OF INFLAMMABLE MATERIALS FROM THE SURFACE IS 8.5 IN.
  • Page 10 I N S TA L L AT I O N CLAMP INSTALLATION This fixture features a mounting point on the yoke for the attachment of a mounting clamp. There is also a safety cable loop located on the rear of the fixture (see the illustration below). When mounting the fixture to a truss or any other suspended or overhead installation, be sure to secure appropriately rated clamps (not included) to the yoke, and attach a separate SAFETY CABLE of the appropriate weight rating to the safety cable loop.
  • Page 11 I N S TA L L AT I O N CONNECTOR PLATE: Each unit includes a connector plate that can be used to secure two adjacent mounted units together. To install the connector plate, follow the directions below: 1. Locate the connector plate. It is affixed to back of the unit, near one of the ends of the bar. See the illustrations below for guidance.
  • Page 12: Remove Device Management

    R E M O T E D E V I C E M A N A G E M E N T NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout the entire system, including DMX data splitters and wireless systems. Remote Device Management (RDM) is a protocol that sits on top of the DMX512 data standard for lighting, and allows the DMX systems of the fixtures to be modified and monitored remotely.
  • Page 13: Control Panel

    C O N T R O L PA N E L The fixture includes an easy to navigate system menu control panel display where all necessary settings and adjustments are made. • MENU: Leave current menu and return to previous menu level. •...
  • Page 14: System Menu

    S Y S T E M M E N U 1 - 507 (6ch) 1 - 504 (9ch) 1 - 500 (13ch) 1 - 497 (16ch) 1 - 495 (18ch) 1 - 481 (32ch) DMX Address 1 - 481 (32Ach) 1 - 475 (38ch) 1 - 470 (43ch) 1 - 449 (64ch)
  • Page 15 S Y S T E M M E N U Standard Stage Dim Modes Architectural Theatre Stage 2 Linear Square Dimmer Curve Inv. Sq. S-Curve Display Backlight Off - 2 min Display Display Lock Off - 10 min No / Yes Display Invert °C / °F Temperature Unit...
  • Page 16 S Y S T E M M E N U FIXTURE TEST Auto Test Fixture Use Hour Total LED Hour LED Use Hour LED On Hour LED Hours Reset Passcode = 011 Temperature FIXTURE Fan State INFORMATION RDM UID xxxxxx Fixture Errors Error Logs Reset Error Log...
  • Page 17: Dmx Setup

    2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the chances of erratic behavior.
  • Page 18 D M X S E T U P DMX ADDRESSING All fixtures should be given a DMX starting address when operating with a DMX controller, in order to ensure that the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen”...
  • Page 19: Dmx Traits

    D M X T R A I T S CHANNEL FUNCTION VALUES 000 - 255 Outer Red, 0% to 100% 000 - 255 Outer Green, 0% to 100% 000 - 255 Outer Blue, 0% to 100% 000 - 255 Inner White, 0% to 100% 000 - 255 Inner White Group 1 000 - 255 Inner White Group 2 000 - 255 Inner White Group 3...
  • Page 20 D M X T R A I T S CHANNEL FUNCTION VALUES Outer Program Macro 000 - 005 No function 006 - 015 Macro1 016 - 025 Macro2 026 - 035 Macro3 036 - 045 Macro4 046 - 055 Macro5 056 - 065 Macro6 066 - 075 Macro7 076 - 085 Macro8...
  • Page 21 D M X T R A I T S CHANNEL FUNCTION VALUES Inner Strobe Effect 000 - 002 Open 003 - 005 Strobe 006 - 050 Ramp up 051 - 100 Ramp down 101 - 150 Ramp up-down 151 - 200 Lightning 201 - 255 Random Inner Strobe Rate, slow to 000 - 255...
  • Page 22 D M X T R A I T S CHANNEL FUNCTION VALUES 000 - 255 Blue 4 000 - 255 Red 5 000 - 255 Green 5 000 - 255 Blue 5 000 - 255 Red 6 000 - 255 Green 6 000 - 255 Blue 6 000 - 255 Red 7 000 - 255 Green 7...
  • Page 23 D M X T R A I T S CHANNEL FUNCTION VALUES 000 - 255 Red 16 000 - 255 Green 16 000 - 255 Blue 16 000 - 255 Red 17 000 - 255 Green 17 000 - 255 Blue 17 000 - 255 Red 18 000 - 255 Green 18 000 - 255 Blue 18...
  • Page 24 D M X T R A I T S CHANNEL FUNCTION VALUES 000 - 255 Green 27 000 - 255 Blue 27 000 - 255 Red 28 000 - 255 Green 28 000 - 255 Blue 28 000 - 255 Red 29 000 - 255 Green 29 000 - 255 Blue 29 000 - 255 Red 30...
  • Page 25: Led Pixel Zones

    L E D P I X E L Z O N E S 6-, 9-, 13-, AND 18-CHANNEL MODE 16-CHANNEL MODE 32-CHANNEL MODE RGB1 RGB2 RGB3 RGB4 White1 White2 White3 White4 White5 White6 White7 White8 RGB5 RGB6 RGB7 RGB8 32A-CHANNEL MODE RGB2 RGB3 RGB5...
  • Page 26: Color Macro Chart

    C O L O R M A C R O C H A R T MACRO NO. DMX VALUE GREEN BLUE 000 - 009 Color1 010 - 017 Color2 018 - 024 Color3 025 - 032 Color4 033 - 039 Color5 040 - 047 Color6...
  • Page 27: Dimmer Modes And Curves

    D I M M E R M O D E S A N D C U R V E S...
  • Page 28: Daisy Chain Power Linking | Cleaning And Maintenance

    Regular inspections are recommended to ensure proper function and extended life. There are no user serviceable parts inside this fixture. Please refer all other service issues to an authorized ADJ service technician. Should you need any spare parts, please order genuine parts from your local ADJ dealer.
  • Page 29: Dimensional Drawings

    D I M E N S I O N S Dimensions are not drawn to scale.
  • Page 30: Specifications

    S P E C I F I C AT I O N S LIGHT SOURCE: • 448 x 0.3W RGB SMD LEDs + 112 x 5W Cool White SMD LEDs • 116 Degree Beam Angle • Color Temperature: Red: 620-630nm. Green: 515-525nm. Blue: 460-470nm. / Cool White: 5000-6500K •...
  • Page 31: Fcc Statement

    FCC STATEMENT This device complies with Part 15 of the FCC Rules ADJ PRODUCTS LLC 6122 S. Eastern Ave, Los Angeles, CA, 90040. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Table of Contents