S t o r m B u i l t - U n d e r H o o d
I n s t r u c t i o n M a n u a l
ST524 / ST854
Contact Caple on 0117 938 7420 for spare parts or www.caple.co.uk

Advertisement

Table of Contents
loading

Summary of Contents for Caple Storm ST524

  • Page 1 S t o r m B u i l t - U n d e r H o o d I n s t r u c t i o n M a n u a l ST524 / ST854 Contact Caple on 0117 938 7420 for spare parts or www.caple.co.uk...
  • Page 2: Table Of Contents

    C O N T E N T S Safety Instructions Environmental Protection Uses Installation Control Panel Timing Lighting Cleaning and Maintenance Caple Contact Details Instruction manual ST524 / ST854 Please keep this instruction manual for future reference...
  • Page 3: Safety Instructions

    W A R N I N G : - The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure they do not play with the appliance. - The cooking surface and the inferior part of the cooker hood must be at a minimum distance of 65 cm.
  • Page 4 - When performing the electrical connections on the appliance, please make sure that the current tap is provided with earth connection and that voltage values correspond to those indicated on the rating label placed inside the appliance itself. - Before carrying out any cleaning or maintaining operations, the appliance needs to be removed from the electric grid.
  • Page 5 - The cooker hood is not intended for outdoor use. - It must only be used as a domestic appliance to extract vapours and remove odours from cooking. Any other usage is not supported by the manufacturer and could be dangerous. - Where a recirculation cooker hood is fitted above a gas hob, please ensure that there is an adequate supply of fresh air into the room in which it is installed.
  • Page 6 - Do not touch the housing or the grease filters until the cooker hood has cooled down. A P P R O P R I A T E U S E : - This appliance is intended to be used in household and similar applications such as: ›...
  • Page 7: Environmental Protection

    Registration can also be completed online by visiting www.caple.co.uk. Ensure you keep your warranty card safe, you may need to show it to Caple Service together with proof of purchase. If you fail to show your warranty card you will incur all repair charges.
  • Page 8 This appliance conforms to all current and applicable energy regulations. To view the Technical Fiche that supports the energy labelling data, please visit the product page on our website www.caple.co.uk. Instruction manual ST524 / ST854 Please keep this instruction manual for future reference...
  • Page 9: Uses

    U S E S The appliance is already arranged both for re-circulation and ducted installation. › In Recirculation mode (Fig.1), the air and fumes conveyed by the appliance are cleaned both by a grease filter and by an active charcoal filter, and put again into circulation through the hole made in the top of the cabinet.
  • Page 10: Installation

    N OT E : For more information on venting, please see our ‘Extraction & Ventilation guide’ available at www.caple.co.uk ATTENTION: AT LEAST TWO PEOPLE ARE NEEDED TO PERFORM THE INSTALLATION. FIG.3 Before installing the appliance, in order not to damage the appliance itself, the metal grease filter should be removed.
  • Page 11 › Make a cut-out in the bottom of the cabinet which is suitable to hold the appliance in position (Fig.4). › Prepare the power supply. › Create a hole for air evacuation. › Adjust the position of the stop side-springs using the appropriate screws, according to the thickness of the board the appliance will be ST524 = 501mm...
  • Page 12 D U C T E D V E R S I O N › Connect the flange to the air evacuation hole with appropriate ducting. › Connect the appliance to the electrical mains through the supply cord. R E C I R C U L AT I N G V E R S I O N ›...
  • Page 13: Control Panel

    C O N T R O L PA N E L C O N T R O L PA N E L A. Light switch on/off A: Light switch on/off B: Motor switch - speed 1 / OFF B. Motor switch - speed 1 / OFF C: Motor switch - speed 2 D: Motor switch - speed 3 C.
  • Page 14: Timing

    T I M I N G › This product is equipped with intelligent electronics which include a timer device for speed controls when the air capacity exceeds 650m³/h. Internal motor models, with maximum air capacity higher than 650m³/h, are equipped with a timer device that automatically switches the speed from 4th to 3rd speed, after 5 minutes operation.
  • Page 15: Lighting

    L I G H T I N G D I M M A B L E L I G H T S F U N C T I O N This function provides for lights dimmability, ranging from 20% to 100%, by continuously pressing the light key on the remote control.
  • Page 16: Cleaning And Maintenance

    › The active charcoal filter will need replacing depending on the use, but at least every six months. To purchase replacement charcoal filters (ST524: 2 x CAP54CF, ST854: 2 x CAP65CF) please visit www.caple.co.uk. 16 Instruction manual ST524 / ST854 Please keep this instruction manual for future reference...
  • Page 17 1. Carefully remove the 2 screws that secure the light. Unplug the unit from the power supply before starting the process. information, please contact Caple service - 0117 938 7420 or service@caple.co.uk Unplug the unit from the power supply before starting the process.
  • Page 18 FIG.3 › To clean the appliance itself, tepid water and neutral detergent are recommended, while abrasive products should be avoided. For steel appliances specialised detergents are recommended (please follow the instructions indicated on the product itself to obtain the FIG.3 desired results).
  • Page 19 R E M O V I N G T H E O I L C AT C H E R : After having removed the grease filters and the charcoal filters, please hold the oil tank up by one hand and loosen the three handles by the other hand (Fig.8). Then let the tank slide downwards taking care to avoid spilling any oil.
  • Page 20: Caple Contact Details

    Caple Service Fourth Way Avonmouth T: 0117 938 1900 Bristol E: service@caple.co.uk BS11 8DW www.caple.co.uk...