Ordering Information - Ametek CH44-VER08 System Manual

Power-line carrier rf hybrids balanced & skewed
Table of Contents

Advertisement

Chapter 1. Ordering Information
1
1 – Base Unit
2 – Chassis Option
Flush Mount
Projection Mount
3 – Quantity of Balanced Hybrids
None
One
Two
Three
Four
4 – Quantity of Skewed Hybrids
None
One
Two
Three
Four
5 – Hybrid Options
None
3
Balanced Combiner
6 – Other Optional Boards (Quantity)
Blank Indicates No Optional Boards
Balance Transformer
PLC Test Board
Notes:
1
Hybrids are shipped with the following defaults:
• All empty chassis slots already have blank rear cover plates installed automatically & are included in the price of the chassis.
Additional spare blank rear cover plates must be purchased separately.
• Viewed from the front, hybrids are inserted into the chassis from left to right. Balanced hybrids first, then followed by any skewed
hybrids.
• Viewed from the front, optional boards are inserted from right to left, with the TS board in the right-most position(s).
2
Max number of boards in a chassis is 4. So the total number of Balanced (B) + Skewed (S) + Optional Boards can not exceed 4.
For example, HYB1RU-FM-B3-S2-N is an invalid number because it calls for 5 hybrids total (B3, S2).
3
Balanced combiner includes interconnecting cables and requires position 3, of the catalog number, to be "B4". This option is for
redundancy in phase-to-phase coupling schemes.
4
Position 6 is only used when an optional board is present. Otherwise this catalog number position is blank. There can be more than
one type of optional board and thus multiple suffix codes.
Fully Loaded Chassis
Hybrids Catalog Number Position
Typical Catalog Number
2
2
2,4
Copyright © AMETEK Power Instruments
1
HYB1RU
HYB1RU
FM
PM
B0
B1
B2
B3
B4
S0
S1
S2
S3
S4
N
B
BT (1–4)
TS (1–4)
2
3
4
5
FM
B2
S1
N
BT1
6

Advertisement

Table of Contents
loading

Table of Contents