Ametek CH44-VER08 System Manual page 14

Power-line carrier rf hybrids balanced & skewed
Table of Contents

Advertisement

Insertion Loss: Input to each Output *
Insertion Loss: End-to-End with 1 Phase Shorted to Ground **
Insertion Loss: End-to-End with 1 Phase Open **
Frequency Range
Max Power for Each LINE Port
Input Impedance of Each LINE Port
TX Path Insertion Loss
RX Path Insertion Loss
April 2023
Table 3–5. Balance Transformer Specifications.
Specification
Frequency Range
Max Power for Input
Output 1 & Output 2 Impedance
Input Impedance
Insertion Loss: End-to-End **
Phase of Input to Output 1
Phase of Input to Output 2
* With Exact Impedance Matching on Output
** With having a Balance Transformer at each end of the line
Table 3–6. Balanced Combiner Specifications.
Specification
Chapter 3. Specifications
Value
30–535 kHz
100 Watts
50 Ohms
50 or 75 Ohms
3.2 dB Max
0.4 dB Max
7 dB Max
6 dB Max
0 degrees
180 degrees
Value
30–535 kHz
25 Watts
50 or 75 Ohms
7 dB Max
0.5 dB Max
Page 3–3

Advertisement