Jøtul F 602 ECO Installation And Operating Instructions Manual page 12

Table of Contents

Advertisement

ENGLISH
4.6 Performance check
Once the product has been assembled, always check the
control handles. These should move easily and work in a
satisfactory manner.
Fig. 14 The Jøtul F 602 ECO is equipped with the
following operating options:
B
Air and ignition vent (A). Adjusts in and out in the horizontal
direction (see fi g. 15-17)
Door handle (B). Opens by lifting the handle up and pulling
out.
12
A
Valve adjustment
Fig. 15
20mm
1
1. Pulled out completely : Open (used during ignition)
Fig. 15b
A
When the match symbol (A) is displayed, the valve is open for
ignition.
Fig. 16
2
2. Edge-to-edge with ash lip: Max air after ignition
Fig. 17
-25mm
3
3. Pushed in: Closed

Advertisement

Table of Contents
loading

Table of Contents