Panasonic CS-S12PKV Operating Instructions Manual page 19

Hide thumbs Also See for CS-S12PKV:
Table of Contents

Advertisement

Available languages

Available languages

The human activity sensor will also scan for area of heat source and movement in a room.
Detection area
120º
7m
The unit judges human activity area for a few seconds before indicator updates. Based on area activeness
horizontal airfl ow direction louver will adjust either fi x at predetermined position or swing left/right periodically.
• The human activity sensor performance is infl uenced by indoor unit location, movement speed, temperature range,
etc.
• The human activity sensor may:
- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidifi er from the sensor's detection
area. They may cause sensor malfunction.
Sunlight Sensor operation
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.
Ambient condition
Mode
Set
COOL/DRY
temperature
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Temperature (°C)
COOL
At left area
Indoor
DBT
Max.
32
Min.
16
Human activity indicator
At center / multiple area
+1 °C
Outdoor
WBT
DBT
23
43
11
16
At right area
ECONAVI is activated,
the unit maintains set
temperature until a high
sunlight intensity is detected.
The sunlight sensor detects
sunlight intensity during
weather or day/night
changes, and the unit adjusts
temperature.
WBT
26
11
19

Advertisement

Chapters

Table of Contents
loading