Gas Furnace; Shipping And Packing List; Safety Information - Lennox Allied Air Enterprises A95DF2V Installation Instructions Manual

Warm air gas furnace/downflow air discharge direct vent & non-direct vent
Table of Contents

Advertisement

Gas Furnace

This Category IV gas furnace is shipped ready for installation
in the downflow position.
The furnace is equipped for installation in natural gas
applications. A conversion kit (ordered separately) is
required for use in LP/propane gas applications.
This unit can be installed as either a Direct Vent or a
Non-Direct Vent gas central furnace.
NOTE: In Direct Vent installations, combustion air is taken
from outdoors and flue gases are discharged outdoors.
Non-Direct Vent installations, combustion air is taken from
indoors or ventilated attic or crawl space and flue gases are
discharged outdoors. See Figures 2A and 2B for application
involving roof termination.
Figure 2A
Figure 2B
Page 4 of 58

Shipping and Packing List

Package 1 of 1 contains:
1 - Assembled Gas Unit
1 - Bag assembly containing the following:
1 - Snap bushing
1 - Snap Plug
1 - Wire tie
1 - Condensate trap
1 - Condensate trap cap
1 - Condensate trap clamp
1 - 2" diameter debris screen
1 - 3/4" Threaded street elbow
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
Please refer to specification sheets for available accessories.

Safety Information

Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must
be performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
As with any mechanical equipment, personal injury can
result from contact with sharp sheet metal edges. Be
careful when you handle this equipment.
DANGER OF EXPLOSION!
There are circumstances in which odorant used with
LP/propane gas can lose its scent. In case of a leak,
LP/propane gas will settle close to the floor and may be
difficult to smell. An LP/propane leak detector should
be installed in all LP applications.
Use only the type of gas approved for use with this furnace.
Refer to unit nameplate.
This unit is CSA International certified to ANSI Z21.47 and
CSA 2.3 standards.
Building Codes
In the USA, installation of gas furnaces must conform with
local building codes. In the absence of local codes, units
must be installed according to the current National Fuel
Gas Code (ANSI Z223.1/NFPA 54). The National Fuel Gas
Code is available from the American National Standards
Institute, Inc., 11 West 42nd Street, New York, NY 10036.
Issue 1621
WARNING
CAUTION
DANGER
507052-04