7.2

Checking

Check the spreader for damage. If the equipment should be found not to be in flawless
condition then it must not be used! In this event, inform your supplier immediately.
Check the spreader arms and tips (damage)
Check the control handle including pushbutton (function)
Check the couplings (damage, dirt)
Check the hand grip (securely fastened)
Check the protective cover (damage)
Check the hoses (damage)
7.3

Installation

Move both control levers on the hydraulic power unit to the „0" position (Fig. 1), pull
off the dust protection cover of the coupling and connect the hydraulic hoses with the spreader
as described in chapter 4.4. In order to avoid contamination then connect the protective caps.
When using the SINGLE coupling, coupling can also be carried out without pressure
(„0" position on power unit not necessary).
When operating a hydraulic power unit observe the operating instructions for the equipment!
Fig. 1