Advertisement

Quick Links

Introduction .....................................................2
Important Safety Instructions ...................3
Location............................................................ 11
How It Works.................................................. 11
Dehumidifier Features................................ 12
Operating Instructions ............................... 12
Frigidaire.com USA 1-800-944-9044
use
Dehumidifier
Care And Cleaning ...................................... 17
Storage ............................................................ 18
Normal Sounds ............................................. 18
Before You Call............................................. 19
Frigidaire.ca Canada 1-800-265-8352
care
&
FFAD6023W1
Model:

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire FFAD6023W1

  • Page 1: Table Of Contents

    Important Safety Instructions ....3 Storage ............18 Location............11 Normal Sounds ..........18 How It Works..........11 Before You Call..........19 Dehumidifier Features........ 12 Major Appliance Limited Warranty..20 Operating Instructions ....... 12 Model: FFAD6023W1 Frigidaire.com USA 1-800-944-9044 Frigidaire.ca Canada 1-800-265-8352...
  • Page 2: Introduction

    INTRODUCTION family Welcome to our Thank you for bringing Frigidaire into your home! your purchase beginning of a long relationship together. This manual is your resource for the use and care of your product. Please read it before using your appliance. Keep it handy for quick reference.
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS • Do not leave children unattended in an WARNING area where the appliance is operating. Do not allow them to sit or stand on the For Your Safety appliance. • This appliance is not intended for use by •...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS WARNING SAFETY PRECAUTIONS CAUTION! Avoid Injury or damage to the FOR FLAMMABLE REFRIGERANT unit or other property • Servicing shall only be performed as recommended equipment • Do not direct airflow at fireplaces or other manufacturer. Maintenance and repair heat related sources as this could cause requiring the assistance of other skilled flare ups.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS • No any open fire or device like switch to conducting work on the system. which may generate spark/arcing shall be b) Work procedure around air conditioner to avoid causing Work shall be undertaken under a ignition of the flammable refrigerant used. controlled procedure so as to minimise Please follow the instruction carefully to the risk of a flammable gas or vapour...
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS equipment is to be surveyed to make sure supply shall be connected to the circuit that there are no flammable hazards or until it is satisfactorily dealt with. If the ignition risks. No Smoking signs shall be fault cannot be corrected immediately displayed.
  • Page 7 IMPORTANT SAFETY INSTRUCTIONS ensuring that this will not exceed the brazing, all of the refrigerant shall be permissible voltage current recovered from the system, or isolated permitted for the equipment in use. (by means of shut off valves) in a part of Intrinsically safe components are the only system remote...
  • Page 8 IMPORTANT SAFETY INSTRUCTIONS 12. Charging procedures e) If a vacuum is not possible, make a manifold so that refrigerant can be In addition to conventional charging removed from various parts of the procedures, the following requirements system. shall followed. Ensure that contamination of different refrigerants f) Make sure that cylinder is situated on the...
  • Page 9 IMPORTANT SAFETY INSTRUCTIONS The recovery equipment shall be in good If compressors or compressor oils are to working order with a set of instructions be removed, ensure that they have been concerning the equipment that is at hand evacuated to an acceptable level to make and shall be suitable for the recovery of certain that flammable refrigerant does flammable refrigerants.
  • Page 10 IMPORTANT SAFETY INSTRUCTIONS Wiring Diagram 16020100002435 TOUCH PANEL /LIGHT P9(orP7/P8/P10) MAIN BOARD P10(orP7/P8/P9) (orCN6/CN6A/CN6B/CN10) P8(orP7/P9/P10) P7(orP8/P9/P10)
  • Page 11: Location

    LOCATION & HOW IT WORKS Location How It Works Selecting a Location When the unit is started, the fan begins to pull moisture-laden across IMPORTANT: dehumidifying coils. The coils condense or 1. Dehumidifier must be operated in an draw moisture from the air, and air flows enclosed area to be most e ective.
  • Page 12: Dehumidifier Features

    DEHUMIDIFIER FEATURES & OPERATING INSTRUCTIONS Dehumidifier Features ELECTRONIC CONTROL Before you begin, thoroughly familiarize yourself with the control panel and all its functions (as shown below). Auto Mode Button Displays Humidity Continue Drain Button Turns Unit On Or O Sets Timer Adjusts Humidity Defrost Indicator Turbo Fan Button...
  • Page 13 OPERATING INSTRUCTIONS 2. To turn the unit on, press the button. The 4. Press the Turbo Fan button to activate the unit will run in Auto mode. In this mode, the Turbo Fan feature. In this feature the unit unit will automatically set a comfortable will run in high fan speed to maximize the humidity and fan speed according to the dehumidification speed.
  • Page 14 OPERATING INSTRUCTIONS 6. When the unit is on, first press the Timer NOTE: button, the Timer O indicator light illuminates. It indicates the Auto Stop program is initiated. Press it again the Time 1. Before entering TIMER setting, make sure On indecator light illuminates.
  • Page 15 1. If the display reads "AS" or "ES" , a sensor failed. Contact your Authorized Frigidaire Service Center. b. Do not move the unit at this time otherwise water may spill on the floor. c. Press sides of bucket gently to unclip the bucket from the unit.
  • Page 16 OPERATING INSTRUCTIONS e. Replace the empty bucket back into the unit and once seated correctly, the unit will start up again. f. You should hear a click when the bucket is in the correct position. 2. Continuous Drainage: a. For continuous drainage operation, you will need a garden hose and a drain nearby to discharge the water into.
  • Page 17: Care And Cleaning

    OPERATING INSTRUCTIONS & CARE AND CLEANING d. Screw garden hose onto h. Select the desired humidity setting and threaded portion of the drain connector. fan speed on the unit for continuous (fig.3) draining to start. NOTE 1. Check the seal between the hose and the drain connector.
  • Page 18: Storage

    STORAGE & NORMAL SOUNDS Normal Sounds Storage When unit is not in use, unplug and use the cord wrap shown for your model type. Dripping Sound The sound of dripping water may be heard during dehumidification cycle. Sound of Rushing Air At the top of the unit, you may hear the sound of rushing air being moved by the fan.
  • Page 19: Before You Call

    • Room Temperature is too low. All models will operate satisfactorily at temperatures greater than 41°F (5°C). Fan noise. • Air is moving through the dehumidifier. This is a normal sound. If These Solutions Fail, Call 1-800-944-9044(US)/1-800-265-8352(Canada) For Frigidaire Service.
  • Page 20: Major Appliance Limited Warranty

    MAJOR APPLIANCE LIMITED WARRANTY Your appliance is covered by a limited one-year warranty for functional repairs only. For one year from your original date of purchase, Electrolux will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used and maintained in accordance with the provided instructions.
  • Page 21 Our home is your home. Visit us if you need help with any of these things: owner support accessories service registration (See your registration card for more information.) Frigidaire.com 1-800-944-9044 Frigidaire.ca 1-800-265-8352 16120300A29013 (July 2019)