READ AND SAVE THESE INSTRUCTIONS

Conversion to Propane Gas

WARNING
Personal injury or death from electrical shock may occur
if the appliance is not installed by a qualified installer or
electrician.
Any additions, changes or conversions required in order
for this appliance to satisfactorily meet the application
needs must be made by a qualified technician.

High Altitude Installation

This appliance has been tested for operation up to an
altitude of 10,000 ft (3,048 m) elevation above sea level.
If desired, for altitudes above 2,000 ft (610 m) elevation
above sea level, adjustments may be made. Burners
should be checked at the lowest setting, if the flame is
not stable the simmer should be increased until the
flame is stable. This can be done by adjusting the
bypass screw in the valve. If flame performance is
satisfactory, adjustment will not be required. It is required
that a Certified Professional make the high altitude
adjustments during installation. High altitude nozzle sets
for natural gas and propane gas are available for
installations at 2,000-6,500 ft (610-1,981 m) or 6,501-
10,000 ft (1,982-3,048 m) if the adjustments using the
bypass screw don't resolve performance issues.