Parametric Eq Menu - Polycom Vortex EF2210 Reference Manual

Polycom ef2210 audio: user guide
Hide thumbs Also See for Vortex EF2210:
Table of Contents

Advertisement

P
EQ M
ARAMETRIC
Parametric EQ
Input/Output EQ
Channel
Band
Filter Type
Frequency
Bandwidth
Gain
Slope
Filter Enable
Figure 22. EF2211/
EF2210 Parametric
EQ submenu
© Polycom, Inc.
ENU
The input equalizer is comprised of up to 5 bands of filtering. The whole group of fil-
ters for the channel can also be enabled/disabled without losing the settings for each
band. For each band, you first select the type of filter from the following: Parametric/
Peaking, High Shelf, Low Shelf, Lowpass, Highpass, Linkwitz-Riley Low, or Link-
witz-Riley High.
Parametric/Peaking.
Center Frequency: in Hz, between 20 Hz and 20,000 Hz in 1 Hz steps.
Bandwidth: in octaves, between 0.05 and 2 octaves in 0.05 octave steps.
Gain: in dB, between -20 and +20 in 1 dB steps.
High Shelf.
Center Frequency: in Hz, between 20 Hz and 20,000 Hz in 1 Hz steps.
Bandwidth: in dB/octave, between 1 and 24 dB/octave, but is always less
than or equal to 1.2 x Gain.
Gain: in dB between -20 and +20 in 1 dB steps.
Low Shelf.
Center Frequency: in Hz, between 20 Hz and 20,000 Hz in 1 Hz steps.
Bandwidth: in dB/octave, between 1 and 24 dB/octave, but is always less
than or equal to 1.2 x Gain.
Gain: in dB between -20 and +20 in 1 dB steps.
Lowpass.
Cutoff Frequency: in Hz, between 20 Hz and 20,000 Hz in 1 Hz steps.
Highpass.
Cutoff Frequency: in Hz, between 20 Hz and 20,000 Hz in 1 Hz steps.
Linkwitz-Riley Low. •Frequency: in Hz, between 20 Hz and 20,000 Hz in 1
Hz steps
Slope between 24 dB/oct and 12 dB/oct
Linkwitz-Riley High. •Frequency: in Hz, between 20 Hz and 20,000 Hz in 1
Hz steps
Slope between 24 dB/oct and 12 dB/oct
Center frequency on Parametric/Peaking is the point with the most (or least) gain.
Bandwidth is the width halfway up the peak (so if the peak is 10 dB, it is the width
between the points where the gain is 5 dB).
Center frequency on shelving filters is the frequency where it crosses the point half-
way between 0 dB and the gain of the filter, halfway up the slope.