B. System #4: Time Clock FLOW DATA & INJECTOR DRAW RATES ......30 C. System #4: Twin Tank DIMENSIONAL DRAWING 3900 TOP MOUNT ....31 D. System #5: 2-5 Tanks, Interlock Mechanical DIMENSIONAL DRAWING 3900 SIDE MOUNT ....32 2-4 Tanks, Interlock Electronic Meter per unit for Mechanical and Electronic TYPICAL INSTALLATIONS ..........
10. On units with a by-pass, place in by-pass position. Turn on the INSTALLATION main water supply. Open a cold soft water tap nearby and let run a few minutes or until the system is free from foreign Water Pressure material (usually solder) that may have resulted from the A minimum of 20 pounds (1.4 bar) of water pressure is installation.
START-UP INSTRUCTIONS CONTINUED 5. Position the valve to the start of the brine tank fill cycle. Ensure water goes into the brine tank at the desired rate. The brine valve drive cam will hold the valve in this position to fill the brine tank for the first regeneration.
3. Return timer to closed position engaging snap retainer in back 3210 & 3220 TIMER SETTING PROCEDURE plate. Make certain all electrical wires locate above snap CONTINUED retainer post. Timer Setting Procedure 2. This slight movement of the manual regeneration knob engages How To Change The Length Of The Backwash Time the program wheel and starts the regeneration program.
Page 23
1800 SERIES BRINE SYSTEM AND DRAIN LINE FLOW CONTROL ASSEMBLY CONTINUED Item No. QTY Part No. Description ..60710-4.0 ..BLFC, 1-inch F x 1-inch M, NPT, 4.0 gpm ..60710-5.0 ..BLFC, 1-inch F x 1-inch M, NPT, 5.0 gpm ..
TROUBLESHOOTING Problem Cause Correction Water conditioner fails to Electrical service to unit has been interrupted. Assure permanent electrical service (check fuse, plug, pull regenerate. chain, or switch) Timer is defective. Replace timer. Power failure. Reset time of day. Hard water. By-pass valve is open.
GENERAL SERVICE HINTS FOR METER WATER CONDITIONER FLOW DIAGRAMS CONTROL 1 Service Position Problem: Softener delivers hard water Reason: Reserve capacity has been exceeded. Correction: Check salt dosage requirements and reset program wheel to provide additional reserve. Reason: Program wheel is not rotating with meter output. Correction: Pull cable out of meter cover and rotate manually.
Page 29
WATER CONDITIONER FLOW DIAGRAMS CONTINUED 3 Brine Position 5 Rapid Rinse Position Hard water enters at valve inlet – flows through injector nozzle Hard water enters at valve inlet – flows through the regeneration and throat to draw brine from the brine tank. Brine flows down valve directly down through the mineral –...
TYPICAL INSTALLATIONS System #4 - Typical Single Tank Installation with System #6 Interlock - Typical Twin Tank Installa- Optional Meter tion with Optional Meter Interlock and No Hard Water Bypass System #5 Interlock - Typical Twin Tank Installa- tion with Optional Meter Interlock and No Hard Water Bypass...
16399-01 ...... End Plug Assembly - White 16345 ......O-ring, 362 16800 ......O-ring, 238 60107-10 3900 Lower Piston - No Hard Water Bypass: 11533 ......Plug, Pipe 1/4-inch 14818 ......Clip Piston Rod 16082 ......Piston - No Hard Water Bypass...
Page 40
KEEP THIS MANUAL FOR FUTURE REFERENCE AND UNIT MAINTENANCE. Product design is subject to change without notice.