5803640-BIM-B-0620
Nomenclature
Product Category
Z = A/C, Single Pkg., R-410A
Product Identifier
W = Pkg AC R410A High Eff
C = Cooling Only
E = Electric Heat
Two Stage Natural Gas Heat Options
N = 2 Stage Gas Aluminized Steel
S = 2 Stage Gas Stainless Steel
P = 2 Stage Low Nox Gas Aluminized Steel
Q = 2 Stage Low Nox Gas Stainless Steel
00 = Cooling Only
B = Standard Static
D = High Static
E = VFD/VAV Std Static
G = VFD/VAV High Static
H = VFD/VAV w/Bypass Std Static
K = VFD/VAV w/Bypass High Static
L = VFD/VAV Customer Std Static
N = VFD/VAV Customer High Static
P = VFD IntelliSpeed Std Static
R = VFD IntelliSpeed High Static
S = VFD w/Byp IntelliSp Std Static
U = VFD w/Byp IntelliSp Hi Static
V = VFD Cust IntelliSp Std Static
X = VFD Cust IntelliSp Hi Static
4
3-5 Ton ZW Model Number Nomenclature
Z
W
-A3 C
Nominal Cooling Capacity
-A3 = 3 Ton
-A4 = 4 Ton
-A5 = 5 Ton
Heat Type
Heat Capacity
Gas MBH Input (Unit Size Allowed)
06 = 60 MBH Input (-A3, -A4)
08 = 80 MBH Input (-A3, -A4, -A5)
12 = 120 MBH Input (-A3, -A4, -A5)
16 = 160 MBH Input (-A5)
Electric Heat (Unit Size Allowed)
03 = 3 KW (-A3)
06 = 6 KW (-A3, -A4, -A5)
09 = 9 KW (-A3, -A4, -A5)
15 = 15KW (-A3, -A4, -A5)
20 = 20 KW (-A4, -A5)
24 = 24 KW (-A5)
Blower Option
A = No Economizer
B = Economizer w/Barometric RLF
D = Economizer w/Power EXH
H = Motorized Damper
00
A 2 A 1
A
A = No Sensors
B = PHM (Phase Monitor)
C = DFS (Dirty Filter Switch)
D = SSD (Supply Air Smoke DET)
E = RSD (Return Air Smoke DET)
F = PHM,DFS
G = PHM,SSD
H = PHM,RSD
J = DFS,SSD
K = DFS,RSD
L = SSD,RSD
M = PHM,DFS,SSD
N = PHM,DFS,RSD
P = PHM,SSD,RSD
Q = DFS,SSD,RSD
R = PHM,DFS,SSD,RSD
Voltage
1 = No Service Options
2 = DSC (Disconnect Switch)
2 = 208/230-3-60
3 = NCO (Non-PWR Conv. Outlet)
4 = 460-3-60
4 = PCO (Powered Conv. Outlet)
5 = 575-3-60
5 = DSC,NCO
6 = DSC,PCO
Outdoor Air Option
A
A 1
A 3
Product Generation
2 = Second Generation
3 = Third Generation
Cabinet Options
A = Std Cabinet
E = SSD (SST Drain Pan)
R = Reverse Drain Pan
Additional Options
1 = STD Throwaway Filter
2 = 2" Pleated Filters (Merv 8)
3 = 4" Pleated Filters (Merv 13)
4 = Coil Guard (CG), STD Filter
5 = 2" Pleated Filter,CG
6 = 4" Pleated Filter,CG
Refrigeration
A = Standard Refrigeration
B = ECC (E-Coat Cond Coil)
C = EEC (E-Coat Evap Coil)
D = HGBP (Hot Gas Bypass)
F = ECC,EEC
G = ECC,EEC,HGBP
J = ECC,HGBP
M = EEC,HGBP
Controls Option
A = Stand Alone Smart Equipment™
C = BACnet MSTP,Mdbs,N2 COM Card
D = CPC Control, DFS, APS
G = Novar UCM Ctrl, DFS, APS
H = Hnywll Excel 10 CTRL,DFS,APS
M = Verasys Single Zone
N = Verasys Change Over Bypass
P = Verasys VAV
Sensors
Service Options