26 | English
Technical data
Digital laser measure
Article number
A)
Measuring range
Measuring range (unfa-
B)
vourable conditions)
A)
Measuring accuracy
Measuring accuracy (unfa-
B)
vourable conditions)
Smallest display unit
General
C)
Operating temperature
Storage temperature
Relative air humidity max.
Max. altitude
Pollution degree accord-
ing to IEC 61010-1
Laser class
Laser type
Divergence of the laser
beam
Automatic switch-off after approx.
– Laser
– Measuring tool (without
measurement)
Batteries
Battery pack (access-
ory)
Type
Article number
USB charging connection
1 609 92A 7P5 | (24.06.2022)
GLM 50-22
GLM 50-23 G
3 601 K72 S..
3 601 K72 V01
0.05–50 m
0.05–20 m
–10 °C to +45 °C
–20 °C to +70 °C
635 nm, < 1 mW
515 nm, < 1 mW
< 1.5 mrad (full angle)
2 × 1.5 V LR6 (AA)
BA 3.7V 1.0Ah A
1 607 A35 0N8
GLM 50-25 G
3 601 K72 V00
±1.5 mm
±3.0 mm
0.5 mm
90 %
2000 m
D)
2
2
515 nm, < 1 mW
20 s
5 min
Li-ion
Type-C®