Daikin Siesta R32 split Series Operation Manual page 2

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Table of contents
Table of contents
1 About the documentation
1.1
About this document..................................................................
2 About the system
2.1
Indoor unit .................................................................................
2.1.1
Indoor unit display.......................................................
2.2
About the user interface ............................................................
2.2.1
Components: User interface .......................................
2.2.2
Status: User interface LCD .........................................
2.2.3
To operate the user interface......................................
3 Before operation
3.1
To fix the user interface to the wall............................................
3.2
To insert the batteries................................................................
3.3
To switch between Fahrenheit and Celsius...............................
3.4
To turn on the power supply......................................................
4 Operation
4.1
Operation range ........................................................................
4.2
When to use which feature........................................................
4.3
Operation mode and temperature setpoint................................
4.3.1
To start/stop operation and to set the temperature.....
4.3.2
Airflow rate ..................................................................
4.3.3
Airflow direction...........................................................
4.3.4
Comfort airflow operation............................................
4.3.5
Powerful operation ......................................................
4.3.6
Econo operation..........................................................
4.3.7
OFF/ON timer operation .............................................
5 Energy saving and optimum operation
6 Maintenance and service
6.1
Overview: Maintenance and service .........................................
6.2
To clean the indoor unit and user interface ...............................
6.3
To clean the front panel.............................................................
6.4
To clean the air filters ................................................................
6.5
To clean the titanium apatite deodorizing filter and the silver
particle filter (Ag-ion filter) ......................................................... 10
6.6
To replace the titanium apatite deodorizing filter and the silver
particle filter (Ag-ion filter) ......................................................... 10
6.7
To close the front panel............................................................. 10
6.8
To take following items into account before a long idle period.. 10
7 Troubleshooting
7.1
Symptoms that are NOT system malfunctions .......................... 11
7.1.1
Symptom: A sound like water flowing is heard ........... 11
7.1.2
Symptom: A blowing sound is heard........................... 11
7.1.3
Symptom: A ticking sound is heard............................. 11
7.1.4
Symptom: A whistling sound is heard ......................... 11
7.1.5
Symptom: A clicking sound during operation or idle
time is heard ............................................................... 11
7.1.6
Symptom: A clapping sound is heard ......................... 11
7.1.7
Symptom: White mist comes out of a unit (Indoor
unit) ............................................................................. 11
7.1.8
Symptom: The units can give off odours..................... 11
7.1.9
Symptom: The outdoor fan rotates while the air
conditioner is not in operation ..................................... 11
7.2
Solving problems based on error codes.................................... 11
8 Disposal
Operation manual
2
1
About the documentation
1.1
About this document
Thank you for purchasing this product. Please:
2
2
▪ Keep the documentation for future reference.
2
Target audience
2
End users
3
INFORMATION
3
3
This appliance is intended to be used by expert or trained
3
users in shops, in light industry, and on farms, or for
4
commercial and household use by lay persons.
4
Documentation set
4
This document is part of a documentation set. The complete set
4
consists of:
4
▪ General safety precautions:
4
▪ Safety instructions that you must read before operating your
5
system
5
▪ Format: Paper (in the box of the indoor unit)
5
5
▪ Operation manual:
5
▪ Quick guide for basic usage
6
▪ Format: Paper (in the box of the indoor unit)
6
6
▪ User reference guide:
6
▪ Detailed step-by-step instructions and background information
6
for basic and advanced usage
7
▪ Format: Digital files on
8
and-manuals/product-information/
8
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.
8
9
The original documentation is written in English. All other languages
9
are translations.
9
2
About the system
WARNING: FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
2.1
Indoor unit
11
CAUTION
Do NOT insert fingers, rods or other objects into the air
inlet or outlet. When the fan is rotating at high speed, it will
cause injury.
INFORMATION
The sound pressure level is less than 70 dBA.
WARNING
▪ Do not modify, disassemble, remove, reinstall or repair
the unit yourself as incorrect dismantling or installation
may cause an electric shock or fire. Contact your
dealer.
11
▪ In case of accidental refrigerant leaks, make sure there
are no naked flames. The refrigerant itself is entirely
safe, non-toxic and mildly flammable, but it will
generate toxic gas when it accidentally leaks into a
room where combustible air from fan heaters, gas
cookers, etc. is present. Always have qualified service
personnel confirm that the point of leakage has been
repaired or corrected before resuming operation.
http://www.daikineurope.com/support-