INTRODUCTION
FLOOR allows practically invisible automation of swing gates.
The automated device consists of an hydraulic underground operator, which transfers the movement to the leaf,
and of an hydraulic control unit integrated within the operator.
FLOOR 850-854-880-884 are fully interchangeable with older
18 for more informations.

INSTALLATION WARNINGS

• Before proceeding with installation, fit a magnetothermal/differential switch with a maximum capacity of 10A
upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening
distance of at least 3mm.
• Keep all the materials contained in the packaging away from children since they pose a potential risk.
• The manufacturer declines all responsibility for improper functioning of the automated device if the original
components and accessories suitable for the specific application are not used.
• After installation, always carefully check proper functioning of the system and the devices used.
• This instruction manual addresses professionals qualified to install "powered equipment" and therefore
requires good technical knowledge and installation in compliance with the regulations in force.
• Maintenance must be carried out by qualified personnel.
• Before carrying out any cleaning or maintenance operation, disconnect the control unit from the main line.
• This product has been designed and constructed exclusively for the use indicated in this documentation. Any
other use may cause damage to the product and be a source of danger.
• Verify the end purpose of the product and take all the necessary safety precautions.
• Use of the products for purposes different from the intended use has not been tested by the manufacturer and
is therefore on full responsibility of the installer.
• Mark the automated device with visible warning plates.
• Warn the user that children or animals should not play or stand near the gate.
• Appropriately protect the dangerous points (for example, using a sensitive edge).
• Check proper installation of the earthing system: connect all the metal parts of doors, gates, etc. and all the
system components to an earth terminal.
• Exclusively use original spare parts for any maintenance or repair operations.
• Do not modify any components of the automated device unless expressly authorised by Gi.Bi.Di.
• Use suitable cable clamps to ensure that the wiring is properly connected mechanically and such that an IP 67
protection degree is maintained.