Short-term power failure

Malfunction image
Close valves V1 / V2.
The current supply is interrupted.
No alarm is displayed.
Cause
Interruption of the voltage supply.
Exceeding the permissible voltage range.
This will trigger the fuses and interrupt the
voltage supply.
V01 /11-038
Installation and Operation Manual BEKOKAT
Measure
The valves close automatically.
When the power is restored, the time of
approx. 6 hours via the K1T
(see E-plan page 6) expires again.
At a reactor temperature between
+ 130 °C and + 150 °C, the RESET function
of K1T can be used (refer to Chapter 6.10).
The valves close automatically.
When the power is restored, the time of
approx. 6 hours via the K1T
(see E-plan page 6) expires again.
At a reactor temperature between
+ 130 °C and + 150 °C, the RESET function
of K1T can be used (refer to Chapter 6.10).
®