Download Print this page

Zokop ESC-45P-4R Operation Instruction page 2

Portable air cooler

Advertisement

B.TECHNICAL SPECIFICATION
MODEL
AIRFLOW
VOLTAGE
ESC-45P-4R
4500cmh
110V/60Hz
ESC-50P-4R
5000cmh
110V/60Hz
7000cmh
110V/60Hz
ESC-60P-5RN
C.OPERATION INSTRUCTION
WATER
DIMENSION
N.W
POWER
(cm)
CAPACITY
120W
40L
49*36.5*97
12.5kg
150W
50L
56*37*110
15kg
200W
70L
66*46*117
20kg
Keypad
Instruction
ON/OFF
Make the cooler start or stop to work.
Model
Timer
Speed
To select low, medium or high fan speed.
Swing
To make the vent auto swing(left and right)
Cooling
To make the pump start to work and activates the cooling function.
Night
D.TROUBLE SHOOTING
Malfunction
Reason
-Operating screen
-No power
stays dark
-Main control board failure
-Fuse is blown
-Panel failure
-Display is normal
-The fan is jammed
But without air
-Cooling pad or dust filter is
Flow or the air
blocked
Speed is too low
-Fan is distorted
-Main control board failure
-Motor does not
-Main control board failure
Respond to control
-Panel failure
panel
-Water leaking
-Drain valve is loose
From drain valve
-Dirt in valve
-Air diffuser/swing
-Synchronous motor burnt out
Function not working
-Crankshaft is broken
-Water drops splash
-Water pipe has come loose
Out of the air diffuser
Note:
This troubleshooting is for reference purposes only. If any technical assistance in needed, please contact
your distributor for service.
Comment
Normal / Natural / Sleep
To select 1H-12H working time
Turn on/off the light of screen.
Solution
-Check unit is plugged in
-Change control board
-Change fuse
-Change panel
-Check to ensure there is nothing
Preventing free rotation of the fan
-Clean the cooling pad and dust filter
-Change the fan
-Change the main control board
-Change the main control board
-Change the panel
-Tighten drain valve nut
-Clean drain valve
-Change synchronous motor
-Change crankshaft
-Check water pipe to top of filter pad
And reattach or tighten as necessary