Fuses - Phase Technology PERFECT PT007 Operation & Installation Manual

Digital phase converter
Hide thumbs Also See for PERFECT PT007:
Table of Contents

Advertisement

For 460V PTE models (PTE4XX), disconnect wires from JL2. You may need to remove the
baffle covering the heatsink to access JL2. Next, use a multi-meter to measure between L1
and L2, then measure between L2 and JL3B. If either capacitance measured is below the
50% Capacitance value in Table 32, contact Phase Technologies for replacement. Be
sure to reconnect wires to JL2 before powering unit on again.

Fuses

There are several replaceable fuses in the converter. Each fuse is assigned a designator,
indicated by its label. Contact the Phase Technologies Service Department for replacement
fuses.
Fuse Designator
JL3B
Figure 31 – Measuring PTE4XX Filter Capacitors
Table 33 – Fuse Information
F1
Inverter Board
F3
Inverter Board
JL1
Disconnect wires from JL2
before measuring.
Locations
250 V Fuse Rating
V4.1
JL2
3 A Fast Blow
3 A Fast Blow
31 |
Page