Baxi Combi 624 Installation And Service Manual page 50

High efficiency wall hung condensing gas boiler
Hide thumbs Also See for Combi 624:
Table of Contents

Advertisement

7 Commissioning
Fig.46
Setting chimney sweep mode
Reset
50
R
2
1
3
0
4
bar
R
PN-0000609
Warning
Ensure that both flue test point plugs are in place after checking
combustion.
Setting maximum and minimum output
1. Turn both control knobs fully anticlockwise and leave for 10 sec­
onds.
2. Turn the DHW knob (
seconds).
3. "304" will appear in the display.
4. Turn the CH knob (
play, indicating maximum output.
5. After checking at maximum turn the CH knob (
wise. "0" will appear in the display, indicating minimum output.
Measuring the combustion
Turn on the domestic hot water tap. Carry out inlet working gas pressure
gas rate and combustion checks.
Once all relevant tests are completed, take out of chimney sweep mode by
turning the DHW control knob clockwise.
Boiler is now ready to use.
1
)
/
turn twice in quick succession (within 2
4
) fully clockwise. "100" will appear in the dis­
) fully anticlock­

Advertisement

Table of Contents
loading

Table of Contents