Download Print this page
Ampfibian MINI-PLUS Quick Start Manual

Ampfibian MINI-PLUS Quick Start Manual

Heavy-duty weatherproof 15a to 10a power adaptor with rcd and mcb

Advertisement

Quick Links

AMPFIBIAN MAX Heavy-Duty Weatherproof 15A to 10A Power Adaptor with RCD and MCB
AMPFIBIAN MAX Heavy-Duty Weatherproof 15A to 10A Power Adaptor with RCD and MCB
Mfgr.# 02897
No. DESCRIPTION
No. DESCRIPTION
1
1
CORD SEAL (LID)
CORD SEAL (LID)
2
2
PLUG LID GASKET
PLUG LID GASKET
3
3
RETAINING CLEAT
RETAINING CLEAT
4 CORD SEAL (BODY)
4 CORD SEAL (BODY)
5
5
PLUG LID LATCH
PLUG LID LATCH
6 15A LEAD (NOT SUPPLIED)
6 LEAD (NOT SUPPLIED)
7
7
PLUG LID
PLUG LID
8 RCBO LID
8 RCD/MCB LID
9 RCD/MCB LID LATCH
9 RCBO LID LATCH
10 LOCKOUT TAG
10 LOCKOUT TAG
11 10A PLUG & FLY-LEAD
11 PLUG & FLY-LEAD
12 SECURITY BRACKET
12 SECURITY BRACKET
13 RCD/MCB
13 RCBO
14 TEST BUTTON
14 RCBO TEST BUTTON
15 RCD/MCB SWITCH
15 RCBO TOGGLE SWITCH
16 RCD/MCB LID GASKET
16 RCBO LID GASKET
Ensure cable is
Ensure cable is
positioned in
positioned in
middle of cleat
middle of cleat
CLEAT (3)
CLEAT
USING THE AMPFIBIAN MAX
USING THE AMPFIBIAN MAX
1. With nothing plugged in, connect MAX
1. With nothing plugged in, connect MAX
plug (11) directly into power supply (wall)
plug (11) directly into power supply (wall)
socket and switch power supply ON.
socket and switch power supply ON.
2. Switch MAX ON (15). If unit trips, unplug
2. Switch MAX ON (15). If unit trips, unplug
it and contact us. DO NOT USE or continue
it and contact us. DO NOT USE or continue
to next step.
to next step.
3. Press test button labelled "T" (14). If
3. Press test button labelled "T" (14). If
switch (15) trips OFF continue to step 4.
switch (15) trips OFF continue to step 4.
If switch (15) DOES NOT trip when test
If switch (15) DOES NOT trip when test
button pressed, unplug the MAX and
button pressed, unplug the MAX and
contact place of purchase. DO NOT use
contact place of purchase. DO NOT use
MAX or continue to step 4.
MAX or continue to step 4.
4. Connect extension cord (6) to the MAX
4. Connect extension cord (6) to the MAX
socket ensuring that the lead is captured
socket ensuring that the lead is captured
by the plug lid (7) and cleat (3). Avoid any
by the plug lid (7) and cleat (3). Avoid any
strain on the lead.
strain on the lead.
5. Connect device directly or via extension
5. Connect device directly or via extension
cord/lead (6).
cord/lead (6).
6. Switch MAX to ON position (15).
6. Switch MAX to ON position (15).
TEST MAX EVERY SIX MONTHS BY
TEST MAX EVERY SIX MONTHS BY
PUSHING THE BUTTON MARKED "T"; RCD
PUSHING THE BUTTON MARKED "T"; RCD
SHOULD TRIP IMMEDIATELY, IF NOT, CALL
SHOULD TRIP IMMEDIATELY, IF NOT, CALL
AN ELECTRICIAN OR CONTACT
AN ELECTRICIAN OR CONTACT
AMPFIBIAN.
AMPFIBIAN.
Both lids (7 & 8) must be latched closed
Both lids (7 & 8) must be latched closed
before use. Inspect seals for damage
before use. Inspect seals for damage
and/or obstruction. Do not use if lids, seals
and/or obstruction. Do not use if lids, seals
or latches are damaged or inoperable.
or latches are damaged or inoperable.
IF AMPFIBIAN MAX TRIPS IN SERVICE
IF AMPFIBIAN MAX TRIPS IN SERVICE
First rule out that the MAX is at fault by
First rule out that the MAX is at fault by
performing the above test procedure. The
performing the above test procedure. The
MAX will trip due to overload or an earth
MAX will trip due to overload or an earth
leakage fault. If you are unsure of the
leakage fault. If you are unsure of the
cause, or you believe there is an earth
cause, or you believe there is an earth
1
2
3
4
5
6
RCBOs will vary from illustration & packaging.
All RCBOs have an up/down toggle switch where UP is ON;
RCD = Residual Current Device
and a test push-button marked "T".
MCB = Miniature Circuit Breaker
If there is a small window with a colour indicator, please ignore it.
RCBO = Combination RCD + MCB
To open RCBO Lid (8), a use coin
or a screwdriver to push the lid
leakage fault, turn off all power and
leakage fault, turn off all power and
contact a licensed electrician. If you
contact a licensed electrician. If you
believe there is an overload, switch off or
believe there is an overload, switch off or
unplug some of the appliances and reset
unplug some of the appliances and reset
the MAX.
the MAX.
The Ampfibian MAX is rated 240 Volts with
The Ampfibian MAX is rated 240 Volts with
a maximum current rating of 10A.
a maximum current rating of 10A.
Do not try to open or repair the MAX
Do not try to open or repair the MAX
yourself. No user-serviceable parts are
yourself. No user-serviceable parts are
inside. If the supply cord is damaged, it
inside. If the supply cord is damaged, it
shall be replaced by the manufacturer or
shall be replaced by the manufacturer or
its service agent in order to avoid a hazard.
its service agent in order to avoid a hazard.
Test the MAX before each use as
Test the MAX before each use as
described in step 3. This device will only
described in step 3. This device will only
protect against faults to earth through the
protect against faults to earth through the
body, but not against active to neutral
body, but not against active to neutral
faults.
faults.
This device must be connected DIRECTLY
This device must be connected DIRECTLY
to an outlet socket. It must not be
to an outlet socket. It must not be
connected via cord extension sets.
connected via cord extension sets.
Wet seals will freeze and will not recover
Wet seals will freeze and will not recover
their shape until thawed. Do not open
their shape until thawed. Do not open
frozen unit until thawed. Opening frozen
frozen unit until thawed. Opening frozen
unit may result in damage to seals.
unit may result in damage to seals.
WARNING: ELECTRICITY CAN BE
WARNING: ELECTRICITY CAN BE
DANGEROUS! RCDs (RESIDUAL CURRENT
DANGEROUS! RCDs (RESIDUAL CURRENT
DEVICES) ARE NOT A SUBSTITUTE FOR
DEVICES) ARE NOT A SUBSTITUTE FOR
BASIC ELECTRICAL SAFETY
BASIC ELECTRICAL SAFETY
PRECAUTIONS. RCDs ARE ADDITIONAL
PRECAUTIONS. RCDs ARE ADDITIONAL
PROTECTION AND WILL NOT PREVENT
PROTECTION AND WILL NOT PREVENT
SHOCK, BUT WILL MINIMISE THE EFFECT.
SHOCK, BUT WILL MINIMISE THE EFFECT.
RCDs WILL TRIP FOR A FAULT BETWEEN
RCDs WILL TRIP FOR A FAULT BETWEEN
THE BODY TO EARTH, BUT NOT FOR
THE BODY TO EARTH, BUT NOT FOR
ACTIVE TO NEUTRAL FAULTS. DO NOT USE
ACTIVE TO NEUTRAL FAULTS. DO NOT USE
LIKE US ON FACEBOOK!
LIKE US ON FACEBOOK!
7
8
9
10
RCD/MCB may vary from
illustration. All RCD/MCBs have an up/down
toggle switch where UP is ON; and a test
push-button marked "T".
Push lid & latch in opposite
directions to open switch lid
and latch (9) apart.
(use coin if hard). Raised
Raised lockout tag (10)
lockout tag (10) stops
stops lid opening.
lid opening.
THIS DEVICE IF IT FAILS TO OPERATE
THIS DEVICE IF IT FAILS TO OPERATE
CORRECTLY IN ACCORDANCE WITH
CORRECTLY IN ACCORDANCE WITH
THESE INSTRUCTIONS.
THESE INSTRUCTIONS.
Do not expose to petrol, oil, solvents,
Do not expose to petrol, oil, solvents,
pool chemicals, etc.!
pool chemicals, etc.!
Do not use in hazardous locations!
Do not use in hazardous locations!
Do not use if damaged!
Do not use if damaged!
Do not disassemble!
Do not disassemble!
Ingress protected to IP55.
Ingress protected to IP55.
Do not submerge in water!
Do not submerge in water!
Remove condensation with a soft
Remove condensation with a soft
absorbent cloth.
absorbent cloth.
Turn off power supply before
Turn off power supply before
handling connections in wet conditions!
handling connections in wet conditions!
Store in a dry place out of
Store in a dry place out of
direct sunlight.
direct sunlight.
Ensure there is no gap visible through
Ensure there is no gap visible through
cord seals when closed! If required, leave
cord seals when closed! If required, leave
lid open until cord seals have fully
lid open until cord seals have fully
recovered.
recovered.
This product is not intended for
This product is not intended for
permanent installation.
permanent installation.
Do not bury!
Do not bury.
Suitable for ordinary and heavy-duty
Suitable for ordinary and heavy-duty
extension leads from 7mm to 12mm
extension leads from 7mm to 12mm
diameter.
diameter.
H-Class rated device for trade and
H-Class rated device for trade and
commercial use.
commercial use.
To be used with 10A (2400W)
To be used with 10A (2400W)
maximum load.
maximum load.
ampfibian.com.au
ampfibian.com.au
ampfibian.co.nz
ampfibian.co.nz
RCD = Residual Current Device
MCB = Miniature Circuit Breaker
RCBO = Combination RCD + MCB
13
ON
14
OFF
15
16
Integrated flip-out
Integrated flip-out
hook for hanging
hook for hanging
Freecall Australia
Freecall Australia
1800 342-426
1800 342-426
11
12
ON
OFF

Advertisement

loading
Need help?

Need help?

Do you have a question about the MINI-PLUS and is the answer not in the manual?

Questions and answers

Summary of Contents for Ampfibian MINI-PLUS

  • Page 1 AMPFIBIAN MAX Heavy-Duty Weatherproof 15A to 10A Power Adaptor with RCD and MCB AMPFIBIAN MAX Heavy-Duty Weatherproof 15A to 10A Power Adaptor with RCD and MCB Mfgr.# 02897 RCD = Residual Current Device MCB = Miniature Circuit Breaker RCBO = Combination RCD + MCB No.
  • Page 2 fire overheating and catching fire Protects people against the Protects people against the effects of electrocution effects of electrocution ADAPTOR RANGE ADAPTOR RANGE PRODUCT PRODUCT MINI-PLUS MINI-PLUS MICRO MICRO MINI MINI RV-PLUS RV-PLUS COUNTRY COUNTRY AUSTRALIA...

This manual is also suitable for:

MicroMiniRv-plusMax02897