Download Print this page
Ampfibian MINI 15A Instructions

Ampfibian MINI 15A Instructions

Power adaptor with rcd and mcb

Advertisement

Quick Links

AMPFIBIAN MINI 15A to 10A Power Adaptor with RCD and MCB
AMPFIBIAN MINI 15A to 10A Power Adaptor with RCD and MCB
Mfgr.# 02234
Mfgr.# 02234
No. DESCRIPTION
No. DESCRIPTION
1
1
POWER PLUG
POWER PLUG
2
2
RCD/MCB ON/OFF SWITCH
RCBO ON/OFF TOGGLE SWITCH
3
3
RCBO TEST BUTTON
RCD/MCB TEST BUTTON
4 SOCKET FOR DEVICE
4 SOCKET FOR DEVICE
RCD = Residual Current Device
RCD = Residual Current Device
MCB = Miniature Circuit Breaker
MCB = Miniature Circuit Breaker
RCBO = Combination RCD + MCB
RCBO = Combination RCD + MCB
If there is a small window with a colour indicator, please ignore it.
USING THE AMPFIBIAN MINI
USING THE AMPFIBIAN MINI
1. With nothing plugged in, connect the
1. With nothing plugged in, connect the
MINI's plug (1) directly into power supply
MINI's plug (1) directly into power supply
(wall) socket and switch power supply ON.
(wall) socket and switch power supply ON.
2. Switch MINI ON (2). If unit trips, unplug it
2. Switch MINI ON (2). If unit trips, unplug it
and contact place of purchase. DO NOT
and contact place of purchase. DO NOT
USE or continue with next step.
USE or continue with next step.
3. Press test button labelled "T" (3). If
3. Press test button labelled "T" (3). If
switch (2) trips OFF continue to step 4. If
switch (2) trips OFF continue to step 4. If
switch (2) DOES NOT trip when test button
switch (2) DOES NOT trip when test button
pressed, unplug the MINI and contact us.
pressed, unplug the MINI and contact us.
DO NOT use MINI or continue to step 4.
DO NOT use MINI or continue to step 4.
4. Connect extension cord or operating
4. Connect extension cord or operating
device to MINI's socket (4). Avoid any strain
device to MINI's socket (4). Avoid any strain
on the lead.
on the lead.
6. Switch MINI to ON position (2).
6. Switch MINI to ON position (2).
TEST MINI EVERY SIX MONTHS BY
TEST MINI EVERY SIX MONTHS BY
PUSHING THE BUTTON MARKED "T"; RCD
PUSHING THE BUTTON MARKED "T"; RCD
SHOULD TRIP IMMEDIATELY, IF NOT, CALL
SHOULD TRIP IMMEDIATELY, IF NOT, CALL
AN ELECTRICIAN OR CONTACT
AN ELECTRICIAN OR CONTACT
AMPFIBIAN.
AMPFIBIAN.
IF AMPFIBIAN MINI TRIPS IN SERVICE
IF AMPFIBIAN MINI TRIPS IN SERVICE
First rule out that the MINI is at fault by
First rule out that the MINI is at fault by
performing the above test procedure.
performing the above test procedure.
The MINI will trip due to overload or an
The MINI will trip due to overload or an
earth leakage fault. If you are unsure of the
earth leakage fault. If you are unsure of the
cause, or you believe there is an earth
cause, or you believe there is an earth
LIMITED WARRANTY
LIMITED WARRANTY
Every Ampfibian product is thoroughly inspected and tested before leaving
Every Ampfibian product is thoroughly inspected and tested before leaving
our factory. Ampfibian Pty. Ltd. limits this warranty against defective
our factory. Ampfibian Pty. Ltd. limits this warranty against defective
workmanship and faulty materials under normal use for twentyfour (24)
workmanship and faulty materials under normal use for twentyfour (24)
months from date of purchase (proof of date of purchase must be
months from date of purchase (proof of date of purchase must be
provided) and undertakes at its option to repair or replace each product or
provided) and undertakes at its option to repair or replace each product or
part thereof on condition that:
part thereof on condition that:
• The product has not been subject to misuse, neglect, accidents or
• The product has not been subject to misuse, neglect, accidents or
alterations;
alterations;
• The unit has been used and maintained as per the instructions.
• The unit has been used and maintained as per the instructions.
Ampfibian Pty. Ltd. is not liable for any consequential damage to either
Ampfibian Pty. Ltd. is not liable for any consequential damage to either
people, work or facilities from using the Ampfibian.
people, work or facilities from using the Ampfibian.
Please ensure Ampfibian is actually faulty before returning it, by testing it
Please ensure Ampfibian is actually faulty before returning it, by testing it
on a different power circuit and with a different appliance. Please see the
on a different power circuit and with a different appliance. Please see the
"Return & Refund Policy" page on our website or contact us for details. All
"Return & Refund Policy" page on our website or contact us for details. All
shipping costs are the responsibility of the customer.
shipping costs are the responsibility of the customer.
Please staple your purchase receipt (or a copy) to this document. You will
Please staple your purchase receipt (or a copy) to this document. You will
be asked to provide a filled-out copy of this form and proof-of-purchase in
be asked to provide a filled-out copy of this form and proof-of-purchase in
the event of a warranty claim.
the event of a warranty claim.
1
1
2
2
3
3
4
4
RCBOs will vary from illustration & packaging.
RCD/MCB may vary from
All RCBOs have an up/down toggle switch where UP is ON;
illustration. All RCD/MCBs have an up/down
toggle switch where UP is ON; and a test
and a test push-button marked "T".
push-button marked "T".
leakage fault, turn off all power and
leakage fault, turn off all power and
contact a licensed electrician.
contact a licensed electrician.
If you believe there is an overload, switch
If you believe there is an overload, switch
off or unplug some of the appliances and
off or unplug some of the appliances and
reset the MINI.
reset the MINI.
The Ampfibian MINI is rated 240 Volts with
The Ampfibian MINI is rated 240 Volts with
a maximum current rating of 10A.
a maximum current rating of 10A.
Do not try to open or repair the MINI
Do not try to open or repair the MINI
yourself. No user-serviceable parts are
yourself. No user-serviceable parts are
inside. If the supply cord is damaged, it
inside. If the supply cord is damaged, it
shall be replaced by the manufacturer or
shall be replaced by the manufacturer or
its service agent in order to avoid a hazard.
its service agent in order to avoid a hazard.
Test the MINI before use as described in
Test the MINI before use as described in
step 3. This device will only protect against
step 3. This device will only protect against
faults to earth through the body, but not
faults to earth through the body, but not
against active to neutral faults.
against active to neutral faults.
This device must be connected DIRECTLY
This device must be connected DIRECTLY
to an outlet socket. It must not be
to an outlet socket. It must not be
connected via cord extension sets.
connected via cord extension sets.
To achieve the Ampfibian MINI's ingress
To achieve the Ampfibian MINI's ingress
protection rating of IP33 (water spray up
protection rating of IP33 (water spray up
to 60 degrees from vertical), it must sit on
to 60 degrees from vertical), it must sit on
a hard floor with the RCD/MCB facing
a hard floor with the RCD/MCB facing
downwards and the markings "THIS WAY
downwards and the markings "THIS WAY
UP" facing upwards. The MINI is intended
UP" facing upwards. The MINI is intended
to be used indoors or undercover.
to be used indoors or undercover.
LIKE US ON FACEBOOK!
LIKE US ON FACEBOOK!
2
3
ON
2
OFF
3
ON
OPERATING POSITION THIS WAY UP!
OFF
WARNING: ELECTRICITY CAN BE
WARNING: ELECTRICITY CAN BE
DANGEROUS! RCDs (RESIDUAL CURRENT
DANGEROUS! RCDs (RESIDUAL CURRENT
DEVICES) ARE NOT A SUBSTITUTE FOR
DEVICES) ARE NOT A SUBSTITUTE FOR
BASIC ELECTRICAL SAFETY
BASIC ELECTRICAL SAFETY
PRECAUTIONS. RCDs ARE ADDITIONAL
PRECAUTIONS. RCDs ARE ADDITIONAL
PROTECTION AND WILL NOT PREVENT
PROTECTION AND WILL NOT PREVENT
SHOCK, BUT WILL MINIMISE THE EFFECT.
SHOCK, BUT WILL MINIMISE THE EFFECT.
RCDs WILL TRIP FOR A FAULT BETWEEN
RCDs WILL TRIP FOR A FAULT BETWEEN
THE BODY TO EARTH, BUT NOT FOR
THE BODY TO EARTH, BUT NOT FOR
ACTIVE TO NEUTRAL FAULTS. DO NOT USE
ACTIVE TO NEUTRAL FAULTS. DO NOT USE
THIS DEVICE IF IT FAILS TO OPERATE
THIS DEVICE IF IT FAILS TO OPERATE
CORRECTLY IN ACCORDANCE WITH
CORRECTLY IN ACCORDANCE WITH
THESE INSTRUCTIONS.
THESE INSTRUCTIONS.
Do not expose to petrol, oil, solvents, pool
Do not expose to petrol, oil, solvents, pool
chemicals, etc.
chemicals, etc.
Do not use in hazardous locations!
Do not use in hazardous locations!
Do not use if damaged!
Do not use if damaged!
Do not disassemble!
Do not disassemble!
Ingress protected to IP33,
Ingress protected to IP33,
recommended for indoor use.
recommended for indoor use.
Do not submerge in water!
Do not submerge in water!
This product is not intended for
This product is not intended for
permanent installation.
permanent installation.
Store in a dry place out of direct sunlight.
Store in a dry place out of direct sunlight.
To be used with 10A (2400W) max. load.
To be used with 10A (2400W) max. load.
If you want an extra year's cover free (three in total),
If you want an extra year's cover free (three in total),
register your warranty online at ampfibian.com.au
register your warranty online at ampfibian.com.au
DATE OF PURCHASE:
DATE OF PURCHASE:
PURCHASED FROM:
PURCHASED FROM:
PURCHASER'S NAME:
PURCHASER'S NAME:
CONTACT INFORMATION:
CONTACT INFORMATION:
Please keep these instructions with you. Only send this form to Ampfibian in
Please keep these instructions with you. Only send this form to Ampfibian in
case of a warranty claim!
case of a warranty claim!
ampfibian.com.au
ampfibian.com.au
ampfibian.co.nz
ampfibian.co.nz
OPERATING
POSITION
THIS WAY UP!
ON
OFF
Freecall Australia
Freecall Australia
1800 342-426
1800 342-426

Advertisement

loading
Need help?

Need help?

Do you have a question about the MINI 15A and is the answer not in the manual?

Questions and answers

Summary of Contents for Ampfibian MINI 15A

  • Page 1 AMPFIBIAN MINI 15A to 10A Power Adaptor with RCD and MCB AMPFIBIAN MINI 15A to 10A Power Adaptor with RCD and MCB Mfgr.# 02234 Mfgr.# 02234 No. DESCRIPTION No. DESCRIPTION POWER PLUG POWER PLUG RCBO ON/OFF TOGGLE SWITCH RCD/MCB ON/OFF SWITCH...
  • Page 2 RATING KEY RATING KEY HOW AMPFIBIANS PROTECT YOU HOW AMPFIBIANS PROTECT YOU Ingress Rating Ingress Rating Impact Impact Rating Rating SOLID SOLID LIQUID LIQUID IP1_ IP1_ IP_1 IP_1 IK04 IK04 FIRE FIRE SHOCK SHOCK LOSS LOSS Protection of the back Protection of the back Protection against Protection against...

This manual is also suitable for:

Mini 10a02234