3-8. Installation of the tilting detect switch

(1) Install the switch unit (No.1) with the SW-MW screws (No.2) so that the switch turns on when the
machine head in initial position is pushed by the machine table.
NOTE The switch unit (No.1) is temporarily fixed at the
back side of the sewing machine bed. Fix it to the
proper place as shown on the right figure.
[Notice] If the switch is not turned on, error [M-038] will occur.

3-9. Installation of the eye guard

(1) Loosen the SW-MW screws (No.2) on the eye guard unit (No.1) then, mount the SW-PW screws
(No.3) to the flat place of the sewing machine with the open guard.
(2) Return the open guard to the initial position then, tighten the SW-MW screws (No.2).
<2>
<1>
<3>
<2>
<1>
<6>
<1>: Switch unit
<2>: SW-MW screw (two screws)
<4>
<5>
<7>
<1>: Eye guard unit
<2>: SW-MW screw
<3>: SW-PW screw (two screws)
- 6 -
<1>: Hinge shaft (two shafts)
<2>: Set screw (two screws)
<3>: Hinge (two hinges)
<4>: Hinge rubber (two rubbers)
<5>: Support plate (two plates)
<6>: Socket bolt (four bolts)
<7>: Flat washer (four washers)
<8>: Head rest
<9>: Safety socket bolt (four bolts)